SU1-80A 80A DC Contactor: Specifications & Selection
The SAYOON SU1-80A is an 80A dc contactor for DC switching. Match the contact arrangement, control supply and connection method to your equipment before ordering.
- Rated load current
- 80A (DC-1)
- Contact voltage
- ≤80V DC
- Contact arrangement
- 1 NO
- Coil voltage examples
- 12V / 24V DC
- Load terminals
- PCB welding
- Duty type
- Continuous
Applications & selection
For PCB integration, check pad layout, creepage and clearance, conductor current capacity and heat removal. The listed load terminal is PCB welding. Confirm coil drive, contact switching duty and installation dimensions before committing the board layout.
Specify your SU1-80A configuration
For SU1-80A, provide the circuit drawing, load and coil voltages, current profile, installation space and quantity. Request the model-specific drawing and confirmation of the selected configuration. See the technical information and drawings below for further details.
FEATURES
SAYOON MODEL IMPLICATION
|
SU1 |
-80A |
-K |
-C |
/□ |
|
|
|
|
|
|
1 |
2 |
3 |
4 |
5 |
|
|
|
|
|
|
1 |
Product type: 1NO | |||||||
|
2 |
Rated current | |||||||
|
3 |
Magnetic holding structure | |||||||
|
4 |
Magnetic blowouts | |||||||
|
5 |
Coil rated voltage: 12V, 24V, 36V, 48V, 60V, 72V etc. | |||||||
USES
TECHNICAL PARAMETERS: (Version 1.33)
|
SAYOON Product Type |
SU1-80A |
| Contact form | 1 NO |
| Coil Rated voltage (DC V) | 6V,12V,24V etc. |
| Contact voltage (DC V) | ≤80V |
| Rated load current of contact (DC-1) | 80A |
| Typical voltage drop across contacts per 100A | ≤80mV |
| The cooling pull-in voltage at (20±5)℃ (V) | ≤70% |
| The cooling drop-out voltage at (20±5)℃ (V) | ≤35%, ≥5% |
| Working voltage range of 40℃ coil | 0.8-1.2Us |
| Drop-out time (n/o contacts to open) | 40ms |
| Pull-in time (n/o contacts to close) | 12ms |
| Maximum bounce time for contact connection | 10ms |
| Maximum bounce time for contact disconnection | 3ms |
| Insulation resistance | 20MΩ |
| Electric strength to resist | 50Hz/60Hz 1000VAC 1minute |
| Typical fault currents which can be ruptured | 600A/5ms at 48V DC |
| Coil power (W) | 5-10 |
| Temperature rise of coil (K) | ≤60 |
| Temperature rise on outgoing terminal (K) | ≤65 |
| Electrical life | 10,000 times |
| Mechanical life | 300,000 times |
| Work specification | Continuous |
| Contact material | Ag alloy |
| Load terminal type | PCB welding |
| Coil terminal type | PCB welding |
Note:As regarding to the different using environments of customers which requires different focus of the functions,and in order to improve the comprehensive properties of our products,sayoon may adjust the coil parameters,temperature rise and so on. The above parameters are for reference only, For details, please refer to the guidelines for selection and use of the SAYOON DC contactor.
LOAD CHARACTERISTIC CURVE
INSTALLATION DIAGRAM

WIRING DIAGRAM

TEMPERATURE CURVE

MECHANICAL ABILITY and USE of the ENVIRONMENT
| Ambient temperature | -40~+70℃ |
| Relative humidity | +20℃ 98% |
| Vibration freq. atthe fixed position | 3G, 1~50Hz amplitude 0.5mm |
| Concussion | (60~100) time/minute、acceleration≤4g |
| Altitude | 2000m |
| Installation direction | Random |
| International protection | IP60 (According IEC60947) |
ORDER INSTRUCTION
|
SAYOON Product Type |
SU1-80A |
| U.N.W. | 190g |
| Package QTY. | 50pcs |
| DIM.(cm) | 36*30*14 |
| Mounting bracket type | PCB plug-in,M4 fixed again |
Request a Custom Quote
Interested in this product? Fill out the form below and our sales team will get back to you within 24 hours.