QZJ200A 200A Normally Open DC Contactor: Specifications & Selection
The SAYOON QZJ200A is a 200A normally open dc contactor for DC switching. Its normally open contact closes when the coil is energized, allowing the control circuit to switch a separate DC load. Select the coil voltage independently from the main-circuit voltage.
- Rated load current
- 200A at 48V DC
- Contact voltage
- ≤150V DC
- Contact arrangement
- 1 NO
- Coil voltage examples
- 12V / 24V / 48V DC
- Load terminals
- M8 Screw
- Duty type
- Continuous
Applications & selection
Use the normally open arrangement where the load should be disconnected in the coil-off state. Review continuous current, motor starting or capacitive inrush, switching frequency and ambient temperature. Confirm DC making and breaking ratings rather than selecting solely by the current in the model name.
Specify your QZJ200A configuration
For QZJ200A, send the load voltage and current, load type, required coil supply, operating duty, auxiliary contact needs, mounting dimensions and quantity. Confirm terminal connections and the selected version against the installation drawing. See the technical information and drawings below for further details.
FEATURES
SAYOON MODEL IMPLICATION
|
QZJ |
200A |
-S |
-□ |
-□ |
■ |
/□ |
|
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
|
1 |
Product type | ||||||||
|
2 |
Rated current | ||||||||
|
3 |
Auxiliary switch: None-Without auxiliary switch; S-With auxiliary switch | ||||||||
|
4 |
Mounting bracket type: M-Horizontal (default) | ||||||||
|
5 |
Other function codes | ||||||||
|
6 |
Other special functions: V-With capacitive load | ||||||||
|
7 |
Coil rated voltage: 12V, 24V, 36V, 48V, 60V, 72V etc. | ||||||||
USES
TECHNICAL PARAMETERS: (Version 1.22)
|
SAYOON Product Type |
QZJ200A |
| Contact form | 1 NO |
| Coil Rated voltage (DC V) | 6V,12V,24V,36V,48V,60V,72V,84V,120V,150V etc. |
| Contact voltage (DC V) | ≤150V |
| Rated load current of contact 48V circuit (A) | 200A |
| Rate load current of contact circuit | ≯80mV |
| The cooling pull-in voltage at (20±5)℃ (V) | ≯70% |
| The cooling drop-out voltage at (20±5)℃ (V) | ≯50%,≮5% |
| Working voltage range of 40℃ coil | 0.8-1.2Us |
| Drop-out time (n/o contacts to open) | 15ms |
| Pull-in time (n/o contacts to close) | 10ms |
| Maximum bounce time for contact connection | 10ms |
| Maximum bounce time for contact disconnection | 3ms |
| Insulation resistance | 20MΩ |
| Electric strength to resist | 50Hz/60Hz 1000VAC 1minute |
| Typical fault currents which can be ruptured | 1000A/5ms at 48V/DC |
| Coil power (W) | Start: 35-65, Keep: 2-6 |
| Temperature rise of coil (K) | ≤40 |
| Temperature rise on outgoing terminal (K) | ≤65 |
| Electrical life | 20,000 times |
| Mechanical life | 300,000 times |
| Work specification | Continuous |
| Contact material | Ag alloy |
| Load terminal type | M8 Screw |
| Coil terminal type | M3 Screw |
LOAD CHARACTERISTIC CURVE
INSTALLATION DIAGRAM

WIRING DIAGRAM

COIL TEMPERATURE CURVE

MECHANICAL ABILITY and USE of the ENVIRONMENT
| Contact lead M10 tightening torque (N.m) | ≯9.0 appropriate |
| Coil lead M3 tightening torque (N.m) | ≯0.8 appropriate |
| Ambient temperature | -25~+70℃ |
| Relative humidity | +20℃ 98% |
| Vibration freq. atthe fixed position | 3G, 1~50Hz amplitude 0.5mm |
| Concussion | (60~100) time/minute、acceleration≤4g |
| Altitude | 2000m |
| Installation direction | Random |
| International Protection | IP40 (According IEC60947) |
ORDER INSTRUCTION
|
SAYOON Product Type |
QZJ200A |
| Mounting bracket type | M Horizontal (default) |
Request a Custom Quote
Interested in this product? Fill out the form below and our sales team will get back to you within 24 hours.