{"id":1074,"date":"2026-05-08T11:52:05","date_gmt":"2026-05-08T03:52:05","guid":{"rendered":"https:\/\/sayoon-dc.com\/?post_type=product&#038;p=1074"},"modified":"2026-07-15T13:57:11","modified_gmt":"2026-07-15T05:57:11","slug":"czwh100a-2t-dpdt-reversing-dc-contactor","status":"publish","type":"product","link":"https:\/\/sayoon-dc.com\/de\/product\/czwh100a-2t-dpdt-reversing-dc-contactor\/","title":{"rendered":"CZWH100A-2T DPDT Wende- Gleichstromsch\u00fctz"},"content":{"rendered":"<h2><strong><span style=\"font-weight: var(--bs-h-font-weight); margin-left: 5px;\">EIGENSCHAFTEN<\/span><\/strong><\/h2>\n<div><\/div>\n<div>\n<div>\u00a01. High current carrying capacity: DPDT DC contactors are designed to withstand high current loads, ensuring reliability and stability under various working conditions.<\/div>\n<div>\u00a02. Double-pole double-throw design: It can control two circuits at the same time, suitable for application scenarios that need to switch different power supplies or loads.<\/div>\n<div>\u00a03. Fast response: The contactor has a fast switching speed, which can achieve efficient circuit control and reduce delays.<\/div>\n<div>\u00a04. Durability: Made of high-quality materials, it has good wear resistance and corrosion resistance, suitable for use in harsh environments.<\/div>\n<div>\u00a05. Safety: Built-in protection mechanism to prevent overload and short circuit, ensuring the safety of equipment and operators.<\/div>\n<div>\u00a06. Easy to install: Compact design and equipped with standardized wiring terminals for quick and easy installation and maintenance.<\/div>\n<div><\/div>\n<div>\u00a0Application areas:<\/div>\n<div>\u00a0&#8211; Motor forward and reverse control<\/div>\n<div>\u00a0&#8211; Power switching of automation equipment<\/div>\n<div>\u00a0&#8211; Control systems for robots and manipulators<\/div>\n<div>\u00a0&#8211; Traffic lights and other control systems<\/div>\n<div>\u00a0DPDT DC contactors are ideal for efficient and reliable circuit control in a variety of industrial and commercial applications.<\/div>\n<\/div>\n<h2><strong>SAYOON-MODELL-IMPLIKATION<\/strong><\/h2>\n<div class=\"product-table\">\n<div class=\"table-wrap\">\n<table border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">CZWH<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">100A<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-2T<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-S<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-C<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-M<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-\u25a1<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">\/24V<\/p>\n<\/td>\n<td rowspan=\"2\" valign=\"bottom\" nowrap=\"nowrap\" width=\"144\">\n<p align=\"center\">\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">1<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">2<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">3<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">4<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">5<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">6<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">7<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">8<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"noborder-table\">\n<div class=\"table-wrap\">\n<table border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">1<\/p>\n<\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><b>Produkttyp<\/b><b><\/b><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">2<\/p>\n<\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><b>Bemessungsstrom<\/b><b><\/b><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">3<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" width=\"648\"><b>Schaltungsstruktur:\u00a0<\/b>Double coil, double circuit, positive and negative switching<b><\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">4<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" width=\"648\"><b>Hilfsschalter: Keiner<\/b>- Ohne Hilfsschalter;\u00a0<b>S<\/b>- Mit Hilfsschalter<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">5<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" width=\"648\"><b>Magnetische Blasung<\/b><b><\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">6<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" width=\"648\"><b>Montagehalterung Typ: M<\/b>-Horizontal (Standard);\u00a0<b>2L<\/b>-Zwei senkrecht;\u00a0<b>4L<\/b>-Four vertical<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">7<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" width=\"648\"><b>Andere Funktionscodes: l<\/b>- Mit Schutzdiode;\u00a0<b>R<\/b>-Mit Vorladewiderstand;\u00a0<b>CO<\/b>-Fortlaufend;\u00a0<b>In<\/b>- Zeitweise<b><\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">8<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" nowrap=\"nowrap\"><b>Spulennennspannung:\u00a0<\/b>12V, 24V, 36V, 48V, 60V, 72V usw.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2><strong>Verwendet<\/strong><\/h2>\n<div>This product have a switching phase contacts, for electric vehicles, telecommunication equipment, engineering machinery, car batteries, electric forklift trucks, trains, ships, electronic control systems such as uninterruptible power supply.<\/div>\n<h2><strong>Technical Parameters:\u00a0 (Version 1.46)<\/strong><\/h2>\n<div>\n<div class=\"table-wrap\">\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\">\n<p align=\"center\">\u00a0<b>SAYOON Produkttyp<\/b><\/p>\n<\/td>\n<td valign=\"center\">\n<p align=\"center\">\u00a0<b>CZWH100A-2T<\/b><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Kontaktformular<\/td>\n<td valign=\"center\">\u00a0Convert the two groups (DPDT)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Spulennennspannung (DC V)<\/td>\n<td valign=\"center\">\u00a06V, 12V, 24V, 36V, 48V, 60V, 72V, 84V, 120V, 150V, 220V usw.<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Ber\u00fchrungsspannung (DC V)<\/td>\n<td valign=\"center\">\u00a0\u2264 80 V<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Nennbetriebsstrom des Kontakts 48V-Stromkreis (DC-1)<\/td>\n<td valign=\"center\">\u00a0100A<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Typischer Spannungsabfall \u00fcber Kontakte pro 100 A<\/td>\n<td valign=\"center\">\u00a0&gt;80 mV<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Die Abfallspannung bei (20\u00b15)\u2103 (V)<\/td>\n<td valign=\"center\">\u00a0\u226f70%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Abfallspannung bei (20\u00b15) \u2103 (V)<\/td>\n<td valign=\"center\">\u00a0\u226f35%,\u226e5%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Arbeitsspannungsbereich der 40\u2103-Spule<\/td>\n<td valign=\"center\">\u00a00,8-1,2 \u00b5s<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Abfallzeit (\u00d6ffnen der Schlie\u00dferkontakte)<\/td>\n<td valign=\"center\">\u00a040 ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Anzugszeit (Schlie\u00dfer)<\/td>\n<td valign=\"center\">\u00a012 ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Maximale Prellzeit f\u00fcr den Kontaktschluss<\/td>\n<td valign=\"center\">\u00a010ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Maximale Prellzeit f\u00fcr Kontaktunterbrechung<\/td>\n<td valign=\"center\">\u00a03 ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Isolationswiderstand<\/td>\n<td valign=\"center\">\u00a020 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Elektrische Durchschlagsfestigkeit<\/td>\n<td valign=\"center\">\u00a050 Hz \/ 60 Hz 1000 VAC 1 Minute<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Typische Fehlerstr\u00f6me, die abgeschaltet werden k\u00f6nnen<\/td>\n<td valign=\"center\">\u00a0800A\/5ms bei 48V DC<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Spulenleistung (W)<\/td>\n<td valign=\"center\">\u00a014-23<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Erw\u00e4rmung der Spule (K)<\/td>\n<td valign=\"center\">\u00a0\u226480<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Temperaturerh\u00f6hung an der Abgangsklemme (K)<\/td>\n<td valign=\"center\">\u00a0\u226465<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Elektrisches Leben<\/td>\n<td valign=\"center\">\u00a020.000-mal<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Mechanisches Leben<\/td>\n<td valign=\"center\">\u00a0300.000 Mal<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Arbeitsanweisung<\/td>\n<td valign=\"center\">\u00a0St\u00e4ndig oder intermittierend (Standardwert)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Kontaktmaterial<\/td>\n<td valign=\"center\">\u00a0Ag-Legierung<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Lastentyp<\/td>\n<td valign=\"center\">\u00a0M8 Schraube<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Spulenanschlussart<\/td>\n<td valign=\"center\">\u00a06,3 mm Flachsteckh\u00fclsen<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Nennlast des Hilfskontakts (optional)<\/td>\n<td valign=\"center\">\u00a02A\/48VDC, 5A\/24VDC<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Normally closed to normally open<\/td>\n<td valign=\"center\">\u00a07ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Normally open to normally closed<\/td>\n<td valign=\"center\">\u00a04ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Zertifizierung von Pr\u00fcfungsorganisationen<\/td>\n<td valign=\"center\">\u00a0CE, FCC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p>Hinweis: Im Hinblick auf die unterschiedlichen Einsatzumgebungen der Kunden, die unterschiedliche Funktionsschwerpunkte erfordern, und um die umfassenden Eigenschaften unserer Produkte zu verbessern, kann Sayoon die Spulenparameter, den Temperaturanstieg und so weiter anpassen. Die obigen Parameter dienen nur als Referenz. F\u00fcr Details beziehen Sie sich bitte auf die Richtlinien zur Auswahl und Verwendung des SAYOON-Gleichstromsch\u00fctzes.<\/p>\n<\/div>\n<h2><strong>Belastungskennlinie<\/strong><\/h2>\n<ul class=\"list-group center-list\">\n<li class=\"list-group-item\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/sev100ad-hv-dc-contactor-detial-4.webp\" alt=\"SEV100AD HV DC Contactor detial (4)\" \/><\/li>\n<li class=\"list-group-item\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/sev100ad-hv-dc-contactor-detial-3.webp\" alt=\"SEV100AD HV-DC-Kontaktor-Details (3)\" \/><\/li>\n<\/ul>\n<h2><strong>Installationsdiagramm<\/strong><\/h2>\n<div class=\"center_img\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/czwh100a-2t.webp\" alt=\"czwh100a-2t\" \/><\/div>\n<h2><strong>Schaltplan<\/strong><\/h2>\n<div class=\"center_img\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/thu-22_e.webp\" alt=\"czw-22_e\" \/><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/thu-22_1_e.webp\" alt=\"czw-22_1_e\" \/><\/div>\n<h2><strong>Temperaturkurve<\/strong><\/h2>\n<div class=\"center_img\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/xqws-sdc15-200a.webp\" alt=\"xqws-sdc15-200a\" \/><\/div>\n<h2><strong>Mechanische F\u00e4higkeiten und Nutzung der Umwelt<\/strong><\/h2>\n<div>\n<div class=\"table-wrap\">\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\">\u00a0Kontaktpunkt f\u00fcr die M8-Anschraubkraft (N.m)<\/td>\n<td valign=\"center\">\u00a0\u226f9.0 angemessen<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Spulenanschluss-Drehmoment (N\u00b7m)<\/td>\n<td valign=\"center\">\u00a0\u226f0,8 angemessen<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Umgebungstemperatur<\/td>\n<td valign=\"center\">\u00a0-25 bis +70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Relative Luftfeuchtigkeit<\/td>\n<td valign=\"center\">\u00a0+20 \u00b0C 98%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Schwingungsfrequenz an der festen Position<\/td>\n<td valign=\"center\">\u00a03G, 1\u201350 Hz Amplitude 0,5 mm<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Gehirnersch\u00fctterung<\/td>\n<td valign=\"center\">\u00a0(60\u2013100) Mal\/Minute, Beschleunigung \u2264 4g<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0H\u00f6he<\/td>\n<td valign=\"center\">\u00a02000m<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Einbauanleitung<\/td>\n<td valign=\"center\">\u00a0Zuf\u00e4llig<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Internationale Schutzkonzepte<\/td>\n<td valign=\"center\">\u00a0IP40 (gem\u00e4\u00df IEC 60947)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2><strong>Bestellungsanweisung<\/strong><\/h2>\n<div>\n<div class=\"table-wrap\">\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\">\n<p align=\"center\"><b>SAYOON Produkttyp<\/b><\/p>\n<\/td>\n<td valign=\"center\">\n<p align=\"center\">\u00a0<b>CZWH100A-2T<\/b><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0U.N.W.<\/td>\n<td valign=\"center\">\u00a0970\u514b<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0U.N.W.(-C-S-M)<\/td>\n<td valign=\"center\">\u00a0980g<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Paketmenge.<\/td>\n<td valign=\"center\">\u00a030 PCS<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Befestigungswinkeltyp<\/td>\n<td valign=\"center\">\u00a0M Horizontal (default), 2L Two vertical, 4L Four vertical<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p>When ordering, please state the following: name, full model, control coil voltage specification, installation frame type, whether with auxiliary contact, order quantity. For example: DC Contactor CZWH100A-2T\/24V 100pcs, indicating the load rated current 100A, without auxiliary contact, default mounting bracket, coil control voltage 24V purchase 100pcs. Special voltage specification products, such as user needs can be special order.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Discover the CZWH100A-2T DPDT DC Contactor for reliable switching solutions. Ideal for various applications. Enhance your project with top performance today!<\/p>","protected":false},"featured_media":1278,"template":"","meta":{"_gspb_post_css":""},"product_brand":[],"product_cat":[50],"product_tag":[],"class_list":["post-1074","product","type-product","status-publish","has-post-thumbnail","product_cat-czw-series-dc-contactor","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/sayoon-dc.com\/de\/wp-json\/wp\/v2\/product\/1074","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sayoon-dc.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sayoon-dc.com\/de\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sayoon-dc.com\/de\/wp-json\/wp\/v2\/media\/1278"}],"wp:attachment":[{"href":"https:\/\/sayoon-dc.com\/de\/wp-json\/wp\/v2\/media?parent=1074"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/sayoon-dc.com\/de\/wp-json\/wp\/v2\/product_brand?post=1074"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/sayoon-dc.com\/de\/wp-json\/wp\/v2\/product_cat?post=1074"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/sayoon-dc.com\/de\/wp-json\/wp\/v2\/product_tag?post=1074"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}