{"id":1524,"date":"2026-05-08T11:53:41","date_gmt":"2026-05-08T03:53:41","guid":{"rendered":"https:\/\/sayoon-dc.com\/?post_type=product&#038;p=1524"},"modified":"2026-07-16T14:27:29","modified_gmt":"2026-07-16T06:27:29","slug":"czk125a-high-current-emergency-switch","status":"publish","type":"product","link":"https:\/\/sayoon-dc.com\/es\/product\/czk125a-high-current-emergency-switch\/","title":{"rendered":"CZK125A High Current Emergency Switch"},"content":{"rendered":"<h2><strong>SAYOON MODEL IMPLICATION<\/strong><\/h2>\n<div class=\"product-table\">\n<div class=\"table-wrap\">\n<table border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">CZK<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">125A<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-\u25a1<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">\n<\/td>\n<td rowspan=\"2\" valign=\"bottom\" nowrap=\"nowrap\" width=\"432\">\n<p align=\"center\">\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">1<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">2<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">3<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"noborder-table\">\n<div class=\"table-wrap\">\n<table border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">1<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\"><b>Product type<\/b><b><\/b><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">2<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><b>Rated current<\/b><b><\/b><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">3<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" width=\"648\"><b>Other function codes: C<\/b>-Magnetic blowouts; <b>S<\/b>-With auxiliary switch; <b>T<\/b>-Blown film; P-With protective board<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2><strong>USES<\/strong><\/h2>\n<div>Emergency stop switches are designed for integration with diverse electric vehicles and associated auxiliary systems, providing reliable safety mechanisms and user-friendly operation.<\/div>\n<h2><strong>TECHNICAL PARAMETERS: (Version 2.38)<\/strong><\/h2>\n<div class=\"table-wrap\">\n<table border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"3\" bgcolor=\"#ffffff\">\n<tbody>\n<tr>\n<td bgcolor=\"#99ccff\">\n<p align=\"center\">\u00a0<strong>SAYOON Product Type<\/strong><\/p>\n<\/td>\n<td>\n<p align=\"center\">\u00a0<strong>CZK125A<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0Rated voltage<\/td>\n<td>\u00a012V,24V etc.<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0Contact circuit rated load current (A)<\/td>\n<td>\u00a0125A<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0Typical voltage drop across contacts per 100A<\/td>\n<td>\u00a0\u226f40mV<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0Insulation Resistance<\/td>\n<td>\u00a020M\u03a9<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0Electric strength to resist<\/td>\n<td>\u00a050Hz\/60Hz 1000VAC 1minute<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0Typical fault currents which can be ruptured<\/td>\n<td>\u00a0800A\/5ms at 48V\/DC<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0Electrical life<\/td>\n<td>\u00a010,000 times<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0Mechanical life<\/td>\n<td>\u00a020,000 times<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0Work specification<\/td>\n<td>\u00a0Continuous<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0Contact form<\/td>\n<td>\u00a01 NC<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0Contact Material<\/td>\n<td>\u00a0Ag alloy<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0Auxiliary contact rated load (optional)<\/td>\n<td>\u00a05A\/24VDC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2><strong>LOAD CHARACTERISTIC CURVE<\/strong><\/h2>\n<ul class=\"list-group center-list\">\n<li class=\"list-group-item\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/czk125a1.webp\" alt=\"CZK125A1\" \/><\/li>\n<li class=\"list-group-item\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/czk125a2.webp\" alt=\"CZK125A2\" \/><\/li>\n<\/ul>\n<h2><strong>INSTALLATION DIAGRAM<\/strong><\/h2>\n<div class=\"center_img\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/czk125a3.webp\" alt=\"CZK125A3\" \/><\/div>\n<h2><strong>WIRING DIAGRAM<\/strong><\/h2>\n<div class=\"center_img\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/czk125a4.webp\" alt=\"CZK125A4\" \/><\/div>\n<h2><strong>OTHER WIRING DIAGRAM<\/strong><\/h2>\n<div class=\"center_img\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/czk125a5.webp\" alt=\"CZK125A5\" \/><\/div>\n<h2><strong>MECHANICAL ABILITY and USE of the ENVIRONMENT<\/strong><\/h2>\n<div class=\"table-wrap\">\n<table border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"3\" bgcolor=\"#ffffff\">\n<tbody>\n<tr>\n<td bgcolor=\"#99ccff\">Contact lead M10 tightening torque (N.m)<\/td>\n<td>\u00a0\u226f9.0 appropriate<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0fixing screw M5 tightening force distangce(N.m)<\/td>\n<td>\u00a0\u226f2.5 appropriate<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0Ambient temperature<\/td>\n<td>\u00a0-25~+70\u2103<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0Relative humidity<\/td>\n<td>\u00a0+20\u2103 98%<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0Vibration freq. atthe fixed position<\/td>\n<td>\u00a03G, 1\uff5e50Hz amplitude 0.5mm<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0Concussion<\/td>\n<td>\u00a0(60\uff5e100) time\/minute\u3001acceleration\u22644g<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0Altitude<\/td>\n<td>\u00a02000m<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0Installation direction<\/td>\n<td>\u00a0Random<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0International protection<\/td>\n<td>\u00a0IP40<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2><strong>ORDER INSTRUCTION<\/strong><\/h2>\n<div>\n<div class=\"table-wrap\">\n<table border=\"1\" width=\"90%\" cellspacing=\"0\" cellpadding=\"3\" bgcolor=\"#ffffff\">\n<tbody>\n<tr>\n<td bgcolor=\"#99ccff\">\n<p align=\"center\"><strong>SAYOON Product Type<\/strong><\/p>\n<\/td>\n<td>\n<p align=\"center\">\u00a0<strong>CZK125A<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0U.N.W.<\/td>\n<td>\u00a0350g<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0Package QTY.<\/td>\n<td>\u00a050 PCS<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#99ccff\">\u00a0Mounting type<\/td>\n<td>\u00a0Opening 25mm installation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div>When placing an order, please provide the following information: name, full model number, whether auxiliary contacts are required, and order quantity. For example: switch and accessories CZK125A 100 pcs, rated load current 20M\u03a9, no auxiliary contacts, default mounting bracket, quantity 100 pcs. For products with special voltage specifications, special orders can be made if required.<\/div>","protected":false},"excerpt":{"rendered":"<p>Discover the CZK125A High Current Emergency Switch for reliable safety and performance. Ideal for critical applications ensuring quick and effective shutdown<\/p>","protected":false},"featured_media":1525,"template":"","meta":{"_gspb_post_css":""},"product_brand":[],"product_cat":[57],"product_tag":[],"class_list":["post-1524","product","type-product","status-publish","has-post-thumbnail","product_cat-switches-and-accessories-series","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/sayoon-dc.com\/es\/wp-json\/wp\/v2\/product\/1524","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sayoon-dc.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sayoon-dc.com\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sayoon-dc.com\/es\/wp-json\/wp\/v2\/media\/1525"}],"wp:attachment":[{"href":"https:\/\/sayoon-dc.com\/es\/wp-json\/wp\/v2\/media?parent=1524"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/sayoon-dc.com\/es\/wp-json\/wp\/v2\/product_brand?post=1524"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/sayoon-dc.com\/es\/wp-json\/wp\/v2\/product_cat?post=1524"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/sayoon-dc.com\/es\/wp-json\/wp\/v2\/product_tag?post=1524"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}