CZW600A Normally Open DC Contactor

CZW600A Normally Open DC Contactor

Discover the CZW600A Normally Open DC Contactor for reliable switching solutions. Ideal for various applications ensuring efficiency and durability. Buy now!
Overview

FEATURES

Normally open DC contactors not only play an important role in electrical control systems, but also play a key role in automation equipment, mechanical control and motor starting. Its simple structure and quick response enable it to work stably in various environments. In addition, with the rise of renewable energy and electric vehicles, the application scope of normally open DC contactors is also expanding. They provide efficient current control solutions in solar power generation systems and electric vehicle charging stations, further promoting the development of electrical engineering technology. Therefore, mastering and applying the knowledge of normally open DC contactors is an important step for electrical engineers to improve their professional skills and meet future challenges.

SAYOON MODEL IMPLICATION

CZW

600A

-S

-K

-2L

-□

/24V

1

2

3

4

5

6

7

1

Product type

2

Rated current

3

Auxiliary switch: None-Without auxiliary switch; S-With auxiliary switch

4

Magetic holding structure: K-Two joint magnetic retention (Single coil, Two joint self-locking); 2K-Three joint magnetic retention (Double coil, Three joint self-locking)

5

Mounting bracket type: 2L-Two vertical (default); M-Horizontal

6

Other function codes: l-With suppressor diode; R-With pre-charged resistance; CO-Continuous; IN-Intermittent

7

Coil rated voltage: 12V, 24V, 36V, 48V, 60V, 72V etc.

Uses

This product have one normally open contact, for electric vehicles, telecommunication equipment, engineering machinery, car batteries, electric forklift trucks, trains, ships, electronic control systems such as uninterruptible power supply.

Technical Parameters:  (Version 1.62)

 SAYOON Product Type

 CZW600A

 Contact form  1 NO
 Coil Rated voltage (DC V)  6V,12V,24V,36V,48V,60V,72V,84V,120V,150V,220V etc.
 Contact voltage (DC V)  ≤60V
 Rated load current of contact 48V circuit (DC-1)  600A
 Typical voltage drop across contacts per 100A  ≯80mV
 The cooling pull-in voltage at (20±5)℃ (V)  ≯70%
 The cooling drop-out voltage at (20±5)℃ (V)  ≯35%,≮5%
 Working voltage range of 40℃ coil  0.8-1.2Us
 Drop-out time (n/o contacts to open)  50ms
 Pull-in time (n/o contacts to close)  50ms
 Maximum bounce time for contact connection  10ms
 Maximum bounce time for contact disconnection  3ms
 Insulation resistance  20MΩ
 Electric strength to resist  50Hz/60Hz 1000VAC 1minute
 Typical fault currents which can be ruptured  1800A/5ms at 48V DC
 Coil power (W)  20-45
 Temperature rise of coil (K)  ≤60
 Temperature rise on outgoing terminal (K)  ≤65
 Electrical life  10,000 times
 Mechanical life  300,000 times
 Work specification  Continuous (default) or Intermittent
 Contact material  Ag alloy
 Load terminal type  2-M8 Screw
 Coil terminal type  6.3mm spade terminals
 Auxiliary contact rated load (optional)  2A/48VDC, 5A/24VDC
 Testing organization certification  CE,FCC

 

Note:As regarding to the different using environments of customers which requires different focus of the functions,and in order to improve the comprehensive properties of our products,sayoon may adjust the coil parameters,temperature rise and so on. The above parameters are for reference only, For details, please refer to the guidelines for selection and use of the SAYOON DC contactor.

Load Characteristic Curve

  • SEV600AH HV DC Contactor detail (3)
  • SEV600AH HV DC Contactor detail (2)

Installation Diagram

czw600aczw600a_1czw600a_2czw600a_3

Wiring Diagram

szj-10-d_e

Temperature Curve

xqws-czw100a

Mechanical Ability And Use Of The Environment

 Contact lead M8 tightening torque (N.m)  ≯9.0 appropriate
 Coil lead-out torque (N.m)  ≯0.8 appropriate
 Ambient temperature  -25~+70℃
 Relative humidity  +20℃ 98%
 Vibration freq. atthe fixed position  3G, 1~50Hz amplitude 0.5mm
 Concussion  (60~100) time/minute、acceleration≤4g
 Altitude  2000m
 Installation direction  Random
 International protection  IP40 (According IEC60947)

Order Instruction

 SAYOON Product Type

 CZW600A

 U.N.W.  1406g
 Mounting bracket type  2L Two Vertical(default), M Horizontal

 

When ordering, please state the following: name, full model, control coil voltage specification, installation frame type, whether with auxiliary contact, order quantity. For example: DC Contactor CZW600A/24V 100pcs, indicating the load rated current 600A, without auxiliary contact, default mounting bracket, coil control voltage 24V purchase 100pcs. Special voltage specification products, such as user needs can be special order.

Request a Custom Quote

Interested in this product? Fill out the form below and our sales team will get back to you within 24 hours.

Formulaire de contact
WhatsApp
Code QR WhatsApp
WeChat
Code WeChat
Téléphone
+86 130 5791 2357
Courriel
sayoon@sayoon.com