Suitable for electric forklift, battery cars, tractors, excavators, brick machine, cleaning vehicles, automotive air-conditioning, communication power supply, uninterruptible power supply, power supply switches such as electroplating electronic control system control circuit, has the advantages of small volume, large load capacity, long service life, easy maintenance and other characteristics, welcomed by users. The products in accordance with the standard of the JB2286-78, JB3974-85, YD / 585-92, YD / T512-92 requirements; the plant and related test unit test, meet the standard requirements, the user use for many years, the maximum to meet user needs, quality and reliable.

SAYOON MODEL IMPLICATION

MZJ -100A -D -S -□ -□ /□
1 2 3 4 5 6 7

1

Product type

2

Rated current

3

Coil type: None – double coil structure; D – Single coil structure

4

Auxiliary switch: None – Without auxiliary switch; S – With auxiliary switch

5

Mounting bracket type: None – M Horizontal (default), E Level embedded, L (N) Vertical, E1 Level embedded single direction

6

Other function codes

7

Coil rated voltage: 6V,12V,24V,36V,48V,60V,72V,84V,120V,150V,220V etc.

USES

This product have one normally open contact, for electric vehicles, telecommunication equipment, engineering machinery, car batteries, electric forklift trucks, trains, ships, electronic control systems such as uninterruptible power supply.

TECHNICAL PARAMETERS: (Version 2.54)

 SAYOON Product Type

MZJ-100D

 Contact form  1 NO
 Coil Rated voltage (DC V)  6V,12V,24V,36V,48V,60V,72V,84V,120V,150V,220V etc.
 Tension de contact (V CC)  ≤60V
 Rated load current of contact 48V circuit (A)  100A
 Typical voltage drop across contacts per 100A  ≤80mV
 The cooling pull-in voltage at (20±5)℃ (V)  ≤70%
 The cooling drop-out voltage at (20±5)℃ (V)  ≤35%, ≥5%
 Working voltage range of 40℃ coil  0.8-1.2Us
 Drop-out time (n/o contacts to open)  20ms
 Pull-in time (n/o contacts to close)  5ms
 Maximum bounce time for contact connection  10ms
 Maximum bounce time for contact disconnection  3ms
 Insulation resistance  20MΩ
 La force électrique à résister  50Hz/60Hz 1000VAC 1minute
 Typical fault currents which can be ruptured  800A/5ms at 48V DC
 Coil power (W)  5-10
 Temperature rise of coil (K)  ≤60
 Temperature rise on outgoing terminal (K)  ≤65
 Vie électrique  20,000 times
 Vie mécanique  300,000 times
 Work specification  Continuous
 Contact material  Ag alloy
 Load terminal type  M6 Screw
 Coil terminal type  M4 Screw
 Auxiliary contact rated load (optional)  2A/48VDC, 5A/24VDC
 Testing organization certification  CCC,CE,FCC,RoHS

Note:As regarding to the different using environments of customers which requires different focus of the functions,and in order to improve the comprehensive properties of our products,sayoon may adjust the coil parameters,temperature rise and so on. The above parameters are for reference only, For details, please refer to the guidelines for selection and use of the SAYOON DC contactor.

LOAD CHARACTERISTIC CURVE

 

 

INSTALLATION DIAGRAM

 

 

WIRING DIAGRAM

TEMPERATURE CURVE

 

MECHANICAL ABILITY and USE of the ENVIRONMENT

 Contact lead M6 tightening torque (N.m)  ≯4.5 appropriate
 Coil lead M4 tightening torque (N.m)  ≯1.2 appropriate
 Ambient temperature  -25~+70℃
 Relative humidity  +20℃ 98%
 Vibration freq. atthe fixed position  3G, 1~50Hz amplitude 0.5mm
 Shock  (60~100) times/minute, acceleration≤4g
 Altitude  2000m
 Installation direction  Random
 International Protection  IP40 (According IEC60947)

ORDER INSTRUCTION

SAYOON Product Type MZJ-100D
U.N.W. 306g
U.G.W. 319g
Package QTY. 100pcs
DIM.(cm) 37.2*32.2*26.5
Mounting bracket type None – M Horizontal (default), E Level embedded, L (N) Vertical, E1 Level embedded single direction

When ordering, please state the following: name, full model, control coil voltage specification, installation frame type, whether with auxiliary contact, order quantity. For example: DC Contactor SZJ100A-D/24V 100pcs, indicating the load rated current 100A, without auxiliary contact, default mounting bracket, coil control voltage 24V purchase 100pcs. Special voltage specification products, such as user needs can be special order.

Request a Custom Quote

Interested in this product? Fill out the form below and our sales team will get back to you within 24 hours.

Formulaire de contact
WhatsApp
Code QR WhatsApp
WeChat
Code WeChat
Téléphone
+86 130 5791 2357
Courriel
sayoon@sayoon.com