{"id":1151,"date":"2026-05-08T11:52:26","date_gmt":"2026-05-08T03:52:26","guid":{"rendered":"https:\/\/sayoon-dc.com\/?post_type=product&#038;p=1151"},"modified":"2026-07-15T11:29:26","modified_gmt":"2026-07-15T03:29:26","slug":"czwj200a-2no-dc-contactor","status":"publish","type":"product","link":"https:\/\/sayoon-dc.com\/fr\/product\/czwj200a-2no-dc-contactor\/","title":{"rendered":"CZWJ200A 2NO DC Contactor"},"content":{"rendered":"<h2><strong><span style=\"font-weight: var(--bs-h-font-weight); margin-left: 5px;\">FEATURES<\/span><\/strong><\/h2>\n<div><\/div>\n<div>\n<div>\u00a0Electric vehicles: driving the future<\/div>\n<div>\u00a0The rise of electric vehicles (EVs) has revolutionized the automotive industry, and the CZWJ200A 2NO DC contactor plays a vital role in this transformation. The contactor is widely used in power control and drive systems for electric vehicles, electric motorcycles, and electric bicycles. Its ability to manage high DC currents ensures that the power supply to the vehicle&#8217;s motor is both efficient and reliable. By facilitating the smooth operation of electric vehicles and improving their overall performance, the CZWJ200A 2NO DC contactor makes a significant contribution to the sustainability and efficiency of modern transportation.<\/div>\n<div><\/div>\n<div>\u00a0Renewable Energy Systems: Ensuring Efficiency<\/div>\n<div>\u00a0As the world turns to renewable energy, the CZWJ200A 2NO DC contactor has found its place in solar and wind power generation systems. In these applications, the contactor is responsible for controlling the switching of DC power, ensuring that the entire system operates safely and efficiently. By managing the current generated by renewable energy, the CZWJ200A 2NO DC contactor helps optimize energy production and distribution. Its reliability in harsh environmental conditions makes it an ideal choice for renewable energy applications, where performance and durability are critical.<\/div>\n<div><\/div>\n<div>\u00a0Industrial Automation: Streamlining Operations<\/div>\n<div>\u00a0In the field of industrial automation, the CZWJ200A 2NO DC contactor is indispensable. It is used to control DC motors, pumps, and other DC loads in various industrial equipment and automation systems. The high reliability and adaptability of the contactor enable it to operate seamlessly in different industrial environments, thereby improving operational efficiency and productivity. By providing precise control of DC loads, the CZWJ200A 2NO DC contactor helps streamline processes, reduce downtime, and improve overall system performance.<\/div>\n<\/div>\n<h2><strong>SAYOON MODEL IMPLICATION<\/strong><\/h2>\n<div class=\"product-table\">\n<div class=\"table-wrap\">\n<table border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">CZWJ<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">200A<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-S<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-C<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-M<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-\u25a1<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">\/24V<\/p>\n<\/td>\n<td rowspan=\"2\" valign=\"bottom\" nowrap=\"nowrap\" width=\"216\">\n<p align=\"center\">\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">1<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">3<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">4<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">5<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">6<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">7<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">8<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"noborder-table\">\n<div class=\"table-wrap\">\n<table border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">1<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\"><b>Product type<\/b><b><\/b><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\"><b>\u00a0<\/b><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">2<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"bottom\" width=\"648\"><b>Rated current<\/b><b><\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">3<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"bottom\" width=\"648\"><b>Auxiliary switch: None<\/b>-Without auxiliary switch;\u00a0<b>S<\/b>-With auxiliary switch<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">4<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"bottom\" width=\"648\"><b>Magnetic blow-out<\/b><b><\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">5<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" width=\"648\"><b>Mounting bracket type: M<\/b>-Horizontal (default);\u00a0<b>L<\/b>-One vertical;\u00a0<b>2L<\/b>-Two vertical<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">6<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" width=\"648\"><b>Other function codes: l<\/b>-With suppressor diode;\u00a0<b>R<\/b>-With pre-charged resistance;\u00a0<b>CO<\/b>-Continuous;\u00a0<b>IN<\/b>-Intermittent<b><\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">7<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"bottom\" nowrap=\"nowrap\"><b>Coil rated voltage:\u00a0<\/b>12V, 24V, 36V, 48V, 60V, 72V etc.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2><strong>Uses<\/strong><\/h2>\n<div>This product have two normally open contact, for electric tricycle, electric machinery and equipment, recreational vehicles, floor sweeper, system, ceramic machine, throwing cars, brick car, clean cars, solar boats<\/div>\n<h2><strong>Technical Parameters:\u00a0 (Version 1.49)<\/strong><\/h2>\n<div>\n<div class=\"table-wrap\">\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\">\n<p align=\"center\">\u00a0<b>SAYOON Product Type<\/b><\/p>\n<\/td>\n<td valign=\"center\">\n<p align=\"center\">\u00a0<b>CZWJ200A<\/b><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Contact form<\/td>\n<td valign=\"center\">\u00a02 NO<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Coil Rated voltage (DC V)<\/td>\n<td valign=\"center\">\u00a06V,12V,24V,36V,48V,60V,72V,84V,120V,150V,220V etc.<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Contact voltage (DC V)<\/td>\n<td valign=\"center\">\u00a0\u226480V<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Rated load current of contact 48V circuit (DC-1)<\/td>\n<td valign=\"center\">\u00a0200A<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Typical voltage drop across contacts per 100A<\/td>\n<td valign=\"center\">\u00a0\u226f80mV<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0The cooling pull-in voltage at (20\u00b15)\u2103 (V)<\/td>\n<td valign=\"center\">\u00a0\u226f70%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0The cooling drop-out voltage at (20\u00b15)\u2103 (V)<\/td>\n<td valign=\"center\">\u00a0\u226f35%,\u226e5%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Working voltage range of 40\u2103 coil<\/td>\n<td valign=\"center\">\u00a00.8-1.2Us<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Drop-out time (n\/o contacts to open)<\/td>\n<td valign=\"center\">\u00a040ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Pull-in time (n\/o contacts to close)<\/td>\n<td valign=\"center\">\u00a012ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Maximum bounce time for contact connection<\/td>\n<td valign=\"center\">\u00a010ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Maximum bounce time for contact disconnection<\/td>\n<td valign=\"center\">\u00a03ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Insulation resistance<\/td>\n<td valign=\"center\">\u00a020M\u03a9<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Electric strength to resist<\/td>\n<td valign=\"center\">\u00a050Hz\/60Hz 1000VAC 1minute<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Typical fault currents which can be ruptured<\/td>\n<td valign=\"center\">\u00a01000A\/5ms at 48V\/DC<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Coil power (W)<\/td>\n<td valign=\"center\">\u00a020-35<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Temperature rise of coil (K)<\/td>\n<td valign=\"center\">\u00a0\u226480<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Temperature rise on outgoing terminal (K)<\/td>\n<td valign=\"center\">\u00a0\u226465<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Electrical life<\/td>\n<td valign=\"center\">\u00a020,000 times<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Mechanical life<\/td>\n<td valign=\"center\">\u00a0300,000 times<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Work specification<\/td>\n<td valign=\"center\">\u00a0Continuous or Intermittent(default)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Contact material<\/td>\n<td valign=\"center\">\u00a0Ag alloy<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Load terminal type<\/td>\n<td valign=\"center\">\u00a0M8 Screw<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Coil terminal type<\/td>\n<td valign=\"center\">\u00a06.3mm spade terminals<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Auxiliary contact rated load (optional)<\/td>\n<td valign=\"center\">\u00a02A\/48VDC, 5A\/24VDC<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Testing organization certification<\/td>\n<td valign=\"center\">\u00a0CE,FCC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p>Note:As regarding to the different using environments of customers which requires different focus of the functions,and in order to improve the comprehensive properties of our products,sayoon may adjust the coil parameters,temperature rise and so on. The above parameters are for reference only, For details, please refer to the guidelines for selection and use of the SAYOON DC contactor.<\/p>\n<\/div>\n<h2><strong>Load Characteristic Curve<\/strong><\/h2>\n<ul class=\"list-group center-list\">\n<li class=\"list-group-item\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/fzsm-200-20k.webp\" alt=\"fzsm-200-20k\" \/><\/li>\n<li class=\"list-group-item\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/sev100ad-hv-dc-contactor-detial-3.webp\" alt=\"SEV100AD HV DC Contactor detial (3)\" \/><\/li>\n<\/ul>\n<h2><strong>Installation Diagram<\/strong><\/h2>\n<div class=\"center_img\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/czwt200a.webp\" alt=\"czwt200a\" \/><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/czwt200a_1.webp\" alt=\"czwt200a_1\" \/><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/czwt200a_2.webp\" alt=\"czwt200a_2\" \/><\/div>\n<h2><strong>Wiring Diagram<\/strong><\/h2>\n<div class=\"center_img\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/thu-22_e.webp\" alt=\"SEV600AH HV DC Contactor detail (4)\" \/><\/div>\n<h2><strong>Temperature Curve<\/strong><\/h2>\n<div class=\"center_img\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/xqws-sdc15-200a.webp\" alt=\"SEV600AH HV DC Contactor detail (4)\" \/><\/div>\n<h2><strong>Mechanical Ability And Use Of The Environment<\/strong><\/h2>\n<div>\n<div class=\"table-wrap\">\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\">\u00a0Contact lead M8 tightening torque (N.m)<\/td>\n<td valign=\"center\">\u00a0\u226f9.0 appropriate<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Coil lead-out torque (N.m)<\/td>\n<td valign=\"center\">\u00a0\u226f0.8 appropriate<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Ambient temperature<\/td>\n<td valign=\"center\">\u00a0-25~+70\u2103<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Relative humidity<\/td>\n<td valign=\"center\">\u00a0+20\u2103 98%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Vibration freq. atthe fixed position<\/td>\n<td valign=\"center\">\u00a03G, 1\uff5e50Hz amplitude 0.5mm<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Concussion<\/td>\n<td valign=\"center\">\u00a0(60\uff5e100) time\/minute\u3001acceleration\u22644g<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Altitude<\/td>\n<td valign=\"center\">\u00a02000m<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Installation direction<\/td>\n<td valign=\"center\">\u00a0Random<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0International protection<\/td>\n<td valign=\"center\">\u00a0IP40 (According IEC60947)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2><strong>Order Instruction<\/strong><\/h2>\n<div>\n<div class=\"table-wrap\">\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\">\n<p align=\"center\">\u00a0<b>SAYOON Product Type<\/b><\/p>\n<\/td>\n<td valign=\"center\">\n<p align=\"center\">\u00a0<b>CZWJ200A<\/b><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0U.N.W.<\/td>\n<td valign=\"center\">\u00a0876g<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Package QTY.<\/td>\n<td valign=\"center\">\u00a040PCS<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Mounting bracket type<\/td>\n<td valign=\"center\">\u00a0M Horizontal (default), 1L One vertical, 2L Two vertical<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p>When ordering, please state the following: name, full model, control coil voltage specification, installation frame type, whether with auxiliary contact, order quantity. For example: DC Contactor CZWJ200A\/24V 100pcs, indicating the load rated current 200A, without auxiliary contact, default mounting bracket, coil control voltage 24V purchase 100pcs. Special voltage specification products, such as user needs can be special order.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Discover the CZWJ200A 2NO DC Contactor for efficient control in your applications. Reliable durable and designed for high performance. Shop now!<\/p>","protected":false},"featured_media":1318,"template":"","meta":{"_gspb_post_css":""},"product_brand":[],"product_cat":[50],"product_tag":[],"class_list":["post-1151","product","type-product","status-publish","has-post-thumbnail","product_cat-czw-series-dc-contactor","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/sayoon-dc.com\/fr\/wp-json\/wp\/v2\/product\/1151","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sayoon-dc.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sayoon-dc.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sayoon-dc.com\/fr\/wp-json\/wp\/v2\/media\/1318"}],"wp:attachment":[{"href":"https:\/\/sayoon-dc.com\/fr\/wp-json\/wp\/v2\/media?parent=1151"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/sayoon-dc.com\/fr\/wp-json\/wp\/v2\/product_brand?post=1151"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/sayoon-dc.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1151"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/sayoon-dc.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1151"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}