{"id":1066,"date":"2026-05-08T11:52:03","date_gmt":"2026-05-08T03:52:03","guid":{"rendered":"https:\/\/sayoon-dc.com\/?post_type=product&#038;p=1066"},"modified":"2026-07-15T13:58:41","modified_gmt":"2026-07-15T05:58:41","slug":"czwh100a-t-spdt-dc-contactor","status":"publish","type":"product","link":"https:\/\/sayoon-dc.com\/it\/product\/czwh100a-t-spdt-dc-contactor\/","title":{"rendered":"Contattore DC SPDT CZWH100A-T"},"content":{"rendered":"<h2><strong><span style=\"font-weight: var(--bs-h-font-weight); margin-left: 5px;\">FEATURES<\/span><\/strong><\/h2>\n<div><\/div>\n<div>\n<div>\u00a0SPDT DC Contactor(Single Pole Double Throw DC Contactor) is an electrical switching device mainly used in DC circuits. The SPDT in its name stands for Single Pole Double Throw, which means that the contactor has one input terminal and two output terminals.<\/div>\n<div><\/div>\n<div>\u00a0Applications:<\/div>\n<div>\u00a0&#8211;\u00a0Motor control: used for forward and reverse control of the motor, and the motor can be reversed by switching the circuit direction.<\/div>\n<div>\u00a0&#8211; Source switching: In situations where switching between two power sources is required, such as backup power systems.<\/div>\n<div>\u00a0&#8211; Signal switching: In automation systems, used for signal selection and switching.<\/div>\n<div>\u00a0&#8211; Lighting control: In the lighting system, it can be used to control the switches of different lights.<\/div>\n<div><\/div>\n<div>\u00a0SPDT DC contactor is a flexible and efficient electrical device suitable for a variety of DC circuit control occasions.<\/div>\n<\/div>\n<h2><strong>IMPLICAZIONE DEL MODELLO SAYOON<\/strong><\/h2>\n<div class=\"product-table\">\n<div class=\"table-wrap\">\n<table border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">CZWH<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">100A<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-T<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-S<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-C<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-M<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-\u25a1<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">\/24V<\/p>\n<\/td>\n<td rowspan=\"2\" valign=\"bottom\" nowrap=\"nowrap\" width=\"144\">\n<p align=\"center\">\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">1<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">2<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">3<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">4<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">5<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">6<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">7<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">8<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"noborder-table\">\n<div class=\"table-wrap\">\n<table border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">1<\/p>\n<\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><b>Tipo di prodotto<\/b><b><\/b><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">2<\/p>\n<\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><b>Corrente nominale<\/b><b><\/b><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">3<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" width=\"648\"><b>Circuit structure:\u00a0<\/b>Single coil, Single circuit<b><\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">4<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" width=\"648\"><b>Auxiliary switch: None<\/b>-Without auxiliary switch;\u00a0<b>S<\/b>-With auxiliary switch<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">5<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" width=\"648\"><b>Magnetic blow-out<\/b><b><\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">6<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" width=\"648\"><b>Mounting bracket type: M<\/b>-Horizontal (default);\u00a0<b>L<\/b>-One vertical;\u00a0<b>2L<\/b>-Two vertical;\u00a0<b>X<\/b>-Oblique;\u00a0<b>2N<\/b>-Rear<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">7<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" width=\"648\"><b>Other function codes: l<\/b>-With suppressor diode;\u00a0<b>R<\/b>-With pre-charged resistance;\u00a0<b>CO<\/b>-Continuous;\u00a0<b>IN<\/b>-Intermittent<b><\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">8<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" nowrap=\"nowrap\"><b>Coil rated voltage:\u00a0<\/b>12V, 24V, 36V, 48V, 60V, 72V etc.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2><strong>Uses<\/strong><\/h2>\n<div>This product have one normally open and one normally close contact, used in electroplating equipment, telecommunication equipment, engineering machinery, electric forklift trucks, trains, uninterruptible power supplies and other electronic control system.<\/div>\n<h2><strong>Technical Parameters:\u00a0 (Version 1.38)<\/strong><\/h2>\n<div>\n<div class=\"table-wrap\">\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\">\n<p align=\"center\">\u00a0<b>Tipo di prodotto SAYOON<\/b><\/p>\n<\/td>\n<td valign=\"center\">\n<p align=\"center\">\u00a0<b>CZWH100A-T<\/b><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Modulo di contatto<\/td>\n<td valign=\"center\">\u00a01 NO 1 NC Convert (SPDT)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Coil Rated voltage (DC V)<\/td>\n<td valign=\"center\">\u00a06V,12V,24V,36V,48V,60V,72V,84V,120V,150V,220V etc.<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Contact voltage (DC V)<\/td>\n<td valign=\"center\">\u00a0\u226480V<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Rated load current of contact 48V circuit (DC-1)<\/td>\n<td valign=\"center\">\u00a0100A<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Caduta di tensione tipica ai capi dei contatti per 100A<\/td>\n<td valign=\"center\">\u00a0\u226f80mV<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0The cooling pull-in voltage at (20\u00b15)\u2103 (V)<\/td>\n<td valign=\"center\">\u00a0\u226f70%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0The cooling drop-out voltage at (20\u00b15)\u2103 (V)<\/td>\n<td valign=\"center\">\u00a0\u226f35%,\u226e5%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Working voltage range of 40\u2103 coil<\/td>\n<td valign=\"center\">\u00a00.8-1.2Us<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Drop-out time (n\/o contacts to open)<\/td>\n<td valign=\"center\">\u00a040ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Pull-in time (n\/o contacts to close)<\/td>\n<td valign=\"center\">\u00a012ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Maximum bounce time for contact connection<\/td>\n<td valign=\"center\">\u00a010ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Maximum bounce time for contact disconnection<\/td>\n<td valign=\"center\">\u00a03ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Insulation resistance<\/td>\n<td valign=\"center\">\u00a020 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Resistenza elettrica<\/td>\n<td valign=\"center\">\u00a050Hz\/60Hz 1000VAC 1 minuto<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Correnti di guasto tipiche che possono essere interrotte<\/td>\n<td valign=\"center\">\u00a0800A\/5ms at 48V DC<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Coil power (W)<\/td>\n<td valign=\"center\">\u00a014-23<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Temperature rise of coil (K)<\/td>\n<td valign=\"center\">\u00a0\u226480<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Temperature rise on outgoing terminal (K)<\/td>\n<td valign=\"center\">\u00a0\u226465<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Vita elettrica<\/td>\n<td valign=\"center\">\u00a020.000 volte<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Vita meccanica<\/td>\n<td valign=\"center\">\u00a0300,000 times<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Specifica di lavoro<\/td>\n<td valign=\"center\">\u00a0Continuous or Intermittent(default)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Contact material<\/td>\n<td valign=\"center\">\u00a0Ag alloy<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Load terminal type<\/td>\n<td valign=\"center\">\u00a0M8 Screw<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Coil terminal type<\/td>\n<td valign=\"center\">\u00a06.3mm spade terminals<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Carico nominale del contatto ausiliario (opzionale)<\/td>\n<td valign=\"center\">\u00a02A\/48VDC, 5A\/24VDC<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Normally closed to normally open<\/td>\n<td valign=\"center\">\u00a07ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Normally open to normally closed<\/td>\n<td valign=\"center\">\u00a04ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Testing organization certification<\/td>\n<td valign=\"center\">\u00a0CE,FCC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p>Note:As regarding to the different using environments of customers which requires different focus of the functions,and in order to improve the comprehensive properties of our products,sayoon may adjust the coil parameters,temperature rise and so on. The above parameters are for reference only, For details, please refer to the guidelines for selection and use of the SAYOON DC contactor.<\/p>\n<\/div>\n<h2><strong>Load Characteristic Curve<\/strong><\/h2>\n<ul class=\"list-group center-list\">\n<li class=\"list-group-item\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/sev100ad-hv-dc-contactor-detial-4.webp\" alt=\"SEV100AD HV DC Contactor detial (4)\" \/><\/li>\n<li class=\"list-group-item\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/sev100ad-hv-dc-contactor-detial-3.webp\" alt=\"SEV100AD HV DC Contactor detial (3)\" \/><\/li>\n<\/ul>\n<h2><strong>Installation Diagram<\/strong><\/h2>\n<div class=\"center_img\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/czwh100a.webp\" alt=\"czwh100a\" \/><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/czwh100a_1.webp\" alt=\"czwh100a_1\" \/><\/div>\n<h2><strong>Wiring Diagram<\/strong><\/h2>\n<div class=\"center_img\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/thu-11-t_e.webp\" alt=\"czw-11-t_e\" \/><\/div>\n<h2><strong>Temperature Curve<\/strong><\/h2>\n<div class=\"center_img\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/xqws-sdc15-200a.webp\" alt=\"xqws-sdc15-200a\" \/><\/div>\n<h2><strong>Mechanical Ability And Use Of The Environment<\/strong><\/h2>\n<div>\n<div class=\"table-wrap\">\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\">Contact lead M8 tightening torque (N.m)<\/td>\n<td valign=\"center\">\u00a0\u226f9,0 appropriato<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Coil lead-out torque (N.m)<\/td>\n<td valign=\"center\">\u00a0\u226f0.8 appropriate<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Temperatura ambiente<\/td>\n<td valign=\"center\">\u00a0-25~+70\u2103<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Umidit\u00e0 relativa<\/td>\n<td valign=\"center\">\u00a0+20 \u00b0C 98%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Frequenza di vibrazione nella posizione fissa<\/td>\n<td valign=\"center\">\u00a03G, ampiezza 1-50 Hz 0,5 mm<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Commozione cerebrale<\/td>\n<td valign=\"center\">\u00a0(60\uff5e100) volte\/minuto, accelerazione \u2264 4g<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Altitudine<\/td>\n<td valign=\"center\">\u00a02000m<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Direzione di installazione<\/td>\n<td valign=\"center\">\u00a0Casuale<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Protezione internazionale<\/td>\n<td valign=\"center\">\u00a0IP40 (According IEC60947)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2><strong>Order Instruction<\/strong><\/h2>\n<div>\n<div class=\"table-wrap\">\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\">\n<p align=\"center\">\u00a0<b>Tipo di prodotto SAYOON<\/b><\/p>\n<\/td>\n<td valign=\"center\">\n<p align=\"center\">\u00a0<b>CZWH100A-T<\/b><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0U.N.W.<\/td>\n<td valign=\"center\">\u00a0508g<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Mounting bracket type<\/td>\n<td valign=\"center\">\u00a0M Horizontal (default), 1L One vertical, 2L Two vertical, X Oblique, 2N Rear<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p>When ordering, please state the following: name, full model, control coil voltage specification, installation frame type, whether with auxiliary contact, order quantity. For example: DC Contactor CZWH100A-T\/24V 100pcs, indicating the load rated current 100A, without auxiliary contact, default mounting bracket, coil control voltage 24V purchase 100pcs. Special voltage specification products, such as user needs can be special order.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Discover the CZWH100A-T SPDT DC Contactor perfect for efficient switching in DC applications. Reliable performance and compact design for your electrical needs<\/p>","protected":false},"featured_media":1274,"template":"","meta":{"_gspb_post_css":""},"product_brand":[],"product_cat":[50],"product_tag":[],"class_list":["post-1066","product","type-product","status-publish","has-post-thumbnail","product_cat-czw-series-dc-contactor","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/sayoon-dc.com\/it\/wp-json\/wp\/v2\/product\/1066","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sayoon-dc.com\/it\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sayoon-dc.com\/it\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sayoon-dc.com\/it\/wp-json\/wp\/v2\/media\/1274"}],"wp:attachment":[{"href":"https:\/\/sayoon-dc.com\/it\/wp-json\/wp\/v2\/media?parent=1066"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/sayoon-dc.com\/it\/wp-json\/wp\/v2\/product_brand?post=1066"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/sayoon-dc.com\/it\/wp-json\/wp\/v2\/product_cat?post=1066"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/sayoon-dc.com\/it\/wp-json\/wp\/v2\/product_tag?post=1066"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}