{"id":1090,"date":"2026-05-08T11:52:09","date_gmt":"2026-05-08T03:52:09","guid":{"rendered":"https:\/\/sayoon-dc.com\/?post_type=product&#038;p=1090"},"modified":"2026-07-15T11:50:08","modified_gmt":"2026-07-15T03:50:08","slug":"czwj100a-2t-4no-dc-contactor","status":"publish","type":"product","link":"https:\/\/sayoon-dc.com\/ru\/product\/czwj100a-2t-4no-dc-contactor\/","title":{"rendered":"CZWJ100A-2T 4NO DC Contactor"},"content":{"rendered":"<h2><strong><span style=\"font-weight: var(--bs-h-font-weight); margin-left: 5px;\">FEATURES<\/span><\/strong><\/h2>\n<div><\/div>\n<div>\n<div><span style=\"font-weight: var(--bs-body-font-weight); text-align: var(--bs-body-text-align);\">\u00a0<\/span>Another significant advantage of the CZWJ200A-2T is its fast response. Contactors are designed to act quickly, allowing for rapid switching of circuits. This feature is critical in applications where an immediate response is required to ensure safe and efficient operation of equipment. The ability to quickly disconnect or connect a circuit can prevent potential hazards and improve the overall safety of the electrical system. In addition, contactors often include overload protection features that automatically disconnect the circuit when the load exceeds a safe level. This protective measure is critical to protecting equipment and operators.<\/div>\n<div><\/div>\n<div>\u00a0The installation design of the CZWJ200A-2T is straightforward, with an emphasis on ease of use. The contactor can be quickly installed using standard mounting methods, a significant advantage for technicians working under tight deadlines. This user-friendly design not only saves installation time, but also reduces the possibility of errors, ensuring that the contactor is correctly set up for optimal performance. The wide range of applications of the CZWJ200A-2T further highlights its versatility, as it is suitable for use in various industries such as power, transportation and machinery.<\/div>\n<div><\/div>\n<div>\u00a0The CZWJ200A-2T 4NO DC contactor is a vital component for anyone working with DC circuits. Its high current rating, multiple normally open contacts, and rugged design make it an excellent choice for high-power applications. With its fast response speed and overload protection, it ensures safe and efficient operation in demanding environments. Its easy installation and wide range of applications further enhance its appeal, making it a top choice for engineers and technicians. As the industry continues to evolve and the demand for reliable DC circuit control continues to grow, the CZWJ200A-2T is expected to play an important role in the future of electrical engineering.<\/div>\n<\/div>\n<h2><strong>SAYOON MODEL IMPLICATION<\/strong><\/h2>\n<div class=\"product-table\">\n<div class=\"table-wrap\">\n<table border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">CZWJ<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">100A<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-2T<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-S<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-C<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-M<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-\u25a1<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">\/24V<\/p>\n<\/td>\n<td rowspan=\"2\" valign=\"bottom\" nowrap=\"nowrap\" width=\"144\">\n<p align=\"center\">\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">1<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">2<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">3<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">4<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">5<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">6<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">7<\/p>\n<\/td>\n<td valign=\"center\" nowrap=\"nowrap\">\n<p align=\"center\">8<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"noborder-table\">\n<div class=\"table-wrap\">\n<table border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">1<\/p>\n<\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><b>Product type<\/b><b><\/b><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">2<\/p>\n<\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><b>Rated current<\/b><b><\/b><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<td valign=\"top\" nowrap=\"nowrap\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">3<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" width=\"648\"><b>Circuit structure<\/b><b><\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">4<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" width=\"648\"><b>Auxiliary switch: None<\/b>-Without auxiliary switch;\u00a0<b>S<\/b>-With auxiliary switch<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">5<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" width=\"648\"><b>Magnetic blow-out<\/b><b><\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">6<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" width=\"648\"><b>Mounting bracket type: M<\/b>-Horizontal (default);\u00a0<b>2L<\/b>-Two vertical;\u00a0<b>4L<\/b>-Four vertical;<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">7<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" width=\"648\"><b>Other function codes: l<\/b>-With suppressor diode;\u00a0<b>R<\/b>-With pre-charged resistance;\u00a0<b>CO<\/b>-Continuous;\u00a0<b>IN<\/b>-Intermittent<b><\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" nowrap=\"nowrap\">\n<p align=\"center\">8<\/p>\n<\/td>\n<td colspan=\"9\" valign=\"top\" nowrap=\"nowrap\"><b>Coil rated voltage:\u00a0<\/b>12V, 24V, 36V, 48V, 60V, 72V etc.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2><strong>Uses<\/strong><\/h2>\n<div>This product have four normally open contact, for electric tricycle, electric machinery and equipment, recreational vehicles, floor sweeper, system, ceramic machine, throwing cars, brick car, clean cars, solar boats<\/div>\n<h2><strong>Technical Parameters:\u00a0 (Version 1.56)<\/strong><\/h2>\n<div>\n<div class=\"table-wrap\">\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\">\n<p align=\"center\">\u00a0<b>SAYOON Product Type<\/b><\/p>\n<\/td>\n<td valign=\"center\">\n<p align=\"center\">\u00a0<b>CZWJ100A-2T<\/b><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Contact form<\/td>\n<td valign=\"center\">\u00a04 NO<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Coil Rated voltage (DC V)<\/td>\n<td valign=\"center\">\u00a06V,12V,24V,36V,48V,60V,72V,84V,120V,150V,220V etc.<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Contact voltage (DC V)<\/td>\n<td valign=\"center\">\u00a0\u226460 \u0412<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Rated load current of contact 48V circuit (DC-1)<\/td>\n<td valign=\"center\">\u00a0100A<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Typical voltage drop across contacts per 100A<\/td>\n<td valign=\"center\">\u00a0\u226f80mV<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0The cooling pull-in voltage at (20\u00b15)\u2103 (V)<\/td>\n<td valign=\"center\">\u00a0\u226f70%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0The cooling drop-out voltage at (20\u00b15)\u2103 (V)<\/td>\n<td valign=\"center\">\u00a0\u226f35%,\u226e5%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Working voltage range of 40\u2103 coil<\/td>\n<td valign=\"center\">\u00a00.8-1.2Us<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Drop-out time (n\/o contacts to open)<\/td>\n<td valign=\"center\">\u00a040ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Pull-in time (n\/o contacts to close)<\/td>\n<td valign=\"center\">\u00a012ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Maximum bounce time for contact connection<\/td>\n<td valign=\"center\">\u00a010ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Maximum bounce time for contact disconnection<\/td>\n<td valign=\"center\">\u00a03ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Insulation resistance<\/td>\n<td valign=\"center\">\u00a020M\u03a9<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Electric strength to resist<\/td>\n<td valign=\"center\">\u00a050Hz\/60Hz 1000VAC 1minute<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Typical fault currents which can be ruptured<\/td>\n<td valign=\"center\">\u00a0800A\/5ms at 48V DC<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Coil power (W)<\/td>\n<td valign=\"center\">\u00a014-23<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Temperature rise of coil (K)<\/td>\n<td valign=\"center\">\u00a0\u226480<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Temperature rise on outgoing terminal (K)<\/td>\n<td valign=\"center\">\u00a0\u226465<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Electrical life<\/td>\n<td valign=\"center\">\u00a020,000 times<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Mechanical life<\/td>\n<td valign=\"center\">\u00a0300,000 times<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Work specification<\/td>\n<td valign=\"center\">\u00a0Continuous or Intermittent(default)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Contact material<\/td>\n<td valign=\"center\">\u00a0Ag alloy<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Load terminal type<\/td>\n<td valign=\"center\">\u00a0M8 Screw<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Coil terminal type<\/td>\n<td valign=\"center\">\u00a06.3mm spade terminals<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Auxiliary contact rated load (optional)<\/td>\n<td valign=\"center\">\u00a02A\/48VDC, 5A\/24VDC<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Testing organization certification<\/td>\n<td valign=\"center\">\u00a0CE,FCC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p>Note:As regarding to the different using environments of customers which requires different focus of the functions,and in order to improve the comprehensive properties of our products,sayoon may adjust the coil parameters,temperature rise and so on. The above parameters are for reference only, For details, please refer to the guidelines for selection and use of the SAYOON DC contactor.<\/p>\n<\/div>\n<h2><strong>Load Characteristic Curve<\/strong><\/h2>\n<ul class=\"list-group center-list\">\n<li class=\"list-group-item\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/sev100ad-hv-dc-contactor-detial-4.webp\" alt=\"SEV100AD HV DC Contactor detial (4)\" \/><\/li>\n<li class=\"list-group-item\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/sev100ad-hv-dc-contactor-detial-3.webp\" alt=\"SEV100AD HV DC Contactor detial (3)\" \/><\/li>\n<\/ul>\n<h2><strong>Installation Diagram<\/strong><\/h2>\n<div class=\"center_img\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/czwj100a-2t.webp\" alt=\"czwj100a-2t\" \/><\/div>\n<h2><strong>Wiring Diagram<\/strong><\/h2>\n<div class=\"center_img\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/thu-40_e.webp\" alt=\"czw-40_e\" \/><\/div>\n<h2><strong>Other Wiring Diagram<\/strong><\/h2>\n<div class=\"center_img\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/thu-40_1_e.webp\" alt=\"czw-40_1_e\" \/><\/div>\n<h2><strong>Temperature Curve<\/strong><\/h2>\n<div class=\"center_img\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/xqws-sdc15-200a.webp\" alt=\"xqws-sdc15-200a\" \/><\/div>\n<h2><strong>Mechanical Ability And Use Of The Environment<\/strong><\/h2>\n<div>\n<div class=\"table-wrap\">\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\">\u00a0Contact lead M8 tightening torque (N.m)<\/td>\n<td valign=\"center\">\u00a0\u226f9.0 appropriate<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Coil lead-out torque (N.m)<\/td>\n<td valign=\"center\">\u00a0\u226f0.8 appropriate<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Ambient temperature<\/td>\n<td valign=\"center\">\u00a0-25~+70\u2103<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Relative humidity<\/td>\n<td valign=\"center\">\u00a0+20\u2103 98%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Vibration freq. atthe fixed position<\/td>\n<td valign=\"center\">\u00a03G, 1\uff5e50Hz amplitude 0.5mm<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Concussion<\/td>\n<td valign=\"center\">\u00a0(60\uff5e100) time\/minute\u3001acceleration\u22644g<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Altitude<\/td>\n<td valign=\"center\">\u00a02000m<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Installation direction<\/td>\n<td valign=\"center\">\u00a0Random<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0International protection<\/td>\n<td valign=\"center\">\u00a0IP40 (According IEC60947)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2><strong>Order Instruction<\/strong><\/h2>\n<div>\n<div class=\"table-wrap\">\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\">\n<p align=\"center\">\u00a0<b>SAYOON Product Type<\/b><\/p>\n<\/td>\n<td valign=\"center\">\n<p align=\"center\">\u00a0<b>CZWJ100A-2T<\/b><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0U.N.W.<\/td>\n<td valign=\"center\">\u00a01000g<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Package QTY.<\/td>\n<td valign=\"center\">\u00a030 PCS<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Meas.(cm)<\/td>\n<td valign=\"center\">\u00a036*32.5*35.5<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Mounting bracket type<\/td>\n<td valign=\"center\">\u00a0M Horizontal (default), 2L Two vertical, 4L Four vertical<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p>When ordering, please state the following: name, full model, control coil voltage specification, installation frame type, whether with auxiliary contact, order quantity. For example: DC Contactor CZWJ100A-2T\/24V 100pcs, indicating the load rated current 100A, without auxiliary contact, default mounting bracket, coil control voltage 24V purchase 100pcs. Special voltage specification products, such as user needs can be special order.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Discover the CZWJ100A-2T 4NO DC Contactor for reliable performance in your projects. Perfect for automation and control needs. Order yours today!<\/p>","protected":false},"featured_media":1286,"template":"","meta":{"_gspb_post_css":""},"product_brand":[],"product_cat":[50],"product_tag":[],"class_list":["post-1090","product","type-product","status-publish","has-post-thumbnail","product_cat-czw-series-dc-contactor","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/sayoon-dc.com\/ru\/wp-json\/wp\/v2\/product\/1090","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sayoon-dc.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sayoon-dc.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sayoon-dc.com\/ru\/wp-json\/wp\/v2\/media\/1286"}],"wp:attachment":[{"href":"https:\/\/sayoon-dc.com\/ru\/wp-json\/wp\/v2\/media?parent=1090"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/sayoon-dc.com\/ru\/wp-json\/wp\/v2\/product_brand?post=1090"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/sayoon-dc.com\/ru\/wp-json\/wp\/v2\/product_cat?post=1090"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/sayoon-dc.com\/ru\/wp-json\/wp\/v2\/product_tag?post=1090"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}