{"id":1397,"date":"2026-05-08T11:53:00","date_gmt":"2026-05-08T03:53:00","guid":{"rendered":"https:\/\/sayoon-dc.com\/?post_type=product&#038;p=1397"},"modified":"2026-11-08T21:26:53","modified_gmt":"2026-11-08T13:26:53","slug":"contactor-dc-niem-phong-bang-nhua-epoxy-dien-ap-cao-hev200","status":"publish","type":"product","link":"https:\/\/sayoon-dc.com\/vi\/product\/hev200-high-voltage-epoxy-resin-sealed-dc-contactor\/","title":{"rendered":"Contactor DC ni\u00eam phong b\u1eb1ng nh\u1ef1a epoxy cao \u00e1p HEV200"},"content":{"rendered":"<h2><strong>FEATURES<\/strong><\/h2>\n<div>\n<div>Suitable for new energy electric vehicles, charging facilities, photovoltaic, wind power generation systems, automotive air conditioning, communication power, UPS, power and other electrical control circuit of the switch control, with small size, large load capacity, no spark, long service life, maintenance simple and other characteristics, by users. 1 DC high voltage power: the product cavity filled with rare mixed gas, arc cooling capacity, 2 control load capacity: with 30A-1000A, working voltage range of 5-1000VDC load capacity; 3 safety: insulation structure, can be in flammable or hazardous environment work, coil and contacts will not oxidation and pollution; 4, compared with similar products small size, light weight, power consumption. The product in accordance with the standard JB2286-78, JB3974-85, YD \/ 585-92, YD \/ T512-92 requirements; after the factory and relevant test unit test, meet the requirements of the standard specification, users use for many years, maximum to meet user needs, quality and reliable.<\/div>\n<\/div>\n<h2><strong>SAYOON MODEL IMPLICATION<\/strong><\/h2>\n<div class=\"product-table\">\n<div class=\"table-wrap\">\n<table border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">HEV<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">200<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-7<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">A<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">D<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">X<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">L<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">-\u25a1<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">\u25a0<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">\/12V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">1<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">2<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">3<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">4<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">5<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">6<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">7<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">8<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">9<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">10<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"noborder-table\">\n<div class=\"table-wrap\">\n<table border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\">\n<p align=\"center\">1<\/p>\n<\/td>\n<td colspan=\"8\" valign=\"bottom\" nowrap=\"nowrap\" width=\"576\"><b>Product type: <\/b>HEV one group circuits; HEVJ two group circuit<b><\/b><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\" width=\"72\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">2<\/p>\n<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><b>Rated current<\/b><b><\/b><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">3<\/p>\n<\/td>\n<td colspan=\"8\" valign=\"bottom\" nowrap=\"nowrap\"><b>Contact Rated Voltage: 1<\/b>-200V; <b>7<\/b>-1000V<b><\/b><\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">4<\/p>\n<\/td>\n<td colspan=\"9\" rowspan=\"5\" valign=\"top\" width=\"648\"><b>Circuit structure:<\/b>\u00a0<b>A<\/b>-Normally open; <b>B<\/b>-Normally closed; <b>F<\/b>-Normally open with one auxiliary switch (the auxiliary switch and main contact have the same structure); <b>G<\/b>-One normally closed with one auxiliary (auxiliary switch and main contact have the same structure). (for other auxiliary switch structures, add 2 or 3 numbers after the model to describe the auxiliary switch structure)<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">5<\/p>\n<\/td>\n<td colspan=\"9\" rowspan=\"7\" valign=\"top\" width=\"648\"><b>Coil type: D<\/b>-Single coil; <b>H<\/b>-With coil economizer; <b>K<\/b>-Two joint magnetic retention (Single coil, Two joint self-locking); <b>2K<\/b>-Three joint magnetic retention (Double coil, Three joint self-locking); <b>P<\/b>-Signal control; <b>R<\/b>-Built-in pre charging type [relay drive] (the left digit of the pre charging function is the pre charging delay time, used to control the coil, the right digit is the resistance value with resistance); <b>Y<\/b>-External pre charging [MOS driver] (The left digit of the pre charging function is the pre charging delay time, and the right digit is used as a lead for controlling the coil. If it is greater than 1, it is the resistance value of the live resistance)<b><\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">6<\/p>\n<\/td>\n<td colspan=\"8\" valign=\"bottom\" width=\"576\"><b>Coil outgoing mode: X<\/b>-Wire (390mm); <b>O<\/b>-Other<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">7<\/p>\n<\/td>\n<td colspan=\"8\" valign=\"bottom\" nowrap=\"nowrap\"><b>Mounting bracket type: L<\/b>-Vertical (default); <b>M<\/b>-Horizontal<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">8<\/p>\n<\/td>\n<td colspan=\"9\" rowspan=\"2\" valign=\"bottom\" width=\"648\"><b>None:<\/b>\u00a0Auxiliary switch and main contact have the same structure (default); <b>-2<\/b>: The structure of auxiliary switch and main contact is opposite; <b>-3<\/b>: Special auxiliary switch structure<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">9<\/p>\n<\/td>\n<td colspan=\"8\" valign=\"bottom\" nowrap=\"nowrap\"><b>Other special functions: V<\/b>-With capacitive type load; <b>N<\/b>-No polarity<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" nowrap=\"nowrap\">\n<p align=\"center\">10<\/p>\n<\/td>\n<td colspan=\"8\" valign=\"bottom\" nowrap=\"nowrap\"><b>Coil rated voltage:<\/b>\u00a012V, 24V, 36V, 48V, 60V, 72V etc.<\/td>\n<td valign=\"bottom\" nowrap=\"nowrap\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2><strong>USES<\/strong><\/h2>\n<div>\n<div>The utility model has the advantages that the utility model is provided with one normally open contact, which is suitable for charging piles, electric four wheeled vehicles, new energy vehicles, energy saving and environmental protection systems, road traffic lighting systems, programmable power supply and uninterruptible power supply equipment.<\/div>\n<\/div>\n<h2><strong>TECHNICAL PARAMETERS: (Version 2.97)<\/strong><\/h2>\n<div class=\"table-wrap\">\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\">\n<p align=\"center\">\u00a0<b>SAYOON Product Type<\/b><\/p>\n<\/td>\n<td valign=\"center\">\n<p align=\"center\">\u00a0<b>HEV200<\/b><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Contact form<\/td>\n<td valign=\"center\">\u00a01 NO(SPST-NO) or 1NC(SPST-NC)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Coil Rated voltage (DC V)<\/td>\n<td valign=\"center\">\u00a0DC6V,12V,24V,36V,48V,60V,72V,84V,120V,150V,DC220V,AC220V etc.<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Contact voltage (DC V)<\/td>\n<td valign=\"center\">\u00a0200V,1000V<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Contact circuit rated load current (DC-1)<\/td>\n<td valign=\"center\">\u00a0200A<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Typical voltage drop across contacts per 100A<\/td>\n<td valign=\"center\">\u00a0\u226f80mV<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0The cooling pull-in voltage at (20\u00b15)\u2103 (V)<\/td>\n<td valign=\"center\">\u00a0\u226f70%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0The cooling drop-out voltage at (20\u00b15)\u2103 (V)<\/td>\n<td valign=\"center\">\u00a0\u226f35%,\u226e5%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Working voltage range of 40\u2103\u00a0coil<\/td>\n<td valign=\"center\">\u00a00.8-1.2Us<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Drop-out time (n\/o contacts to open)<\/td>\n<td valign=\"center\">\u00a030ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Pull-in time (n\/o contacts to close)<\/td>\n<td valign=\"center\">\u00a05ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Maximum bounce time for contact connection<\/td>\n<td valign=\"center\">\u00a010ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Maximum bounce time for contact disconnection<\/td>\n<td valign=\"center\">\u00a07ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Insulation Resistance<\/td>\n<td valign=\"center\">\u00a0100M\u03a9<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Electric strength to resist<\/td>\n<td valign=\"center\">\u00a050Hz\/60Hz 2200VAC 1minute<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Typical fault currents which can be ruptured<\/td>\n<td valign=\"center\">\u00a01000A\/5ms at 48V DC<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Coil power (W)<\/td>\n<td valign=\"center\">\u00a0D: 8-20; H: Start 30-50, Keep 1.5-4<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Temperature rise of coil (K)<\/td>\n<td valign=\"center\">\u00a0\u226455<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Temperature rise on outgoing terminal (K)<\/td>\n<td valign=\"center\">\u00a0\u226465<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Electrical life<\/td>\n<td valign=\"center\">\u00a020,000 times<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Mechanical life<\/td>\n<td valign=\"center\">\u00a0300,000 times<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Work specification<\/td>\n<td valign=\"center\">\u00a0Continuous<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Contact material<\/td>\n<td valign=\"center\">\u00a0Alloy<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Inrush time (max)<\/td>\n<td valign=\"center\">\u00a0130ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Maximum switching current<\/td>\n<td valign=\"center\">\u00a02000A 320VDC (more than once)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Maximum switching power<\/td>\n<td valign=\"center\">\u00a0640kW<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Load terminal type<\/td>\n<td valign=\"center\">\u00a0M8 Screw<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Coil terminal type<\/td>\n<td valign=\"center\">\u00a00.3 square silicone wire, 390mm long<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Auxiliary contact rated load (optional)<\/td>\n<td valign=\"center\">\u00a03A\/30VDC<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Testing organization certification<\/td>\n<td valign=\"center\">\u00a0CCC,CE,FCC,RoHS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div>\n<div>Note:As regarding to the different using environments of customers which requires different focus of the functions,and in order to improve the comprehensive properties of our products,sayoon may adjust the coil parameters,temperature rise and so on. The above parameters are for reference only, For details, please refer to the guidelines for selection and use of the SAYOON DC contactor.<\/div>\n<\/div>\n<h2><strong>LOAD CHARACTERISTIC CURVE<\/strong><\/h2>\n<ul class=\"list-group center-list\">\n<li class=\"list-group-item\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/fzsm-200-20k.webp\" alt=\"fzsm-200-20k\" \/><\/li>\n<li class=\"list-group-item\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/fzsj-200-1000.webp\" alt=\"fzsj-200-1000\" \/><\/li>\n<\/ul>\n<h2><strong>INSTALLATION DIAGRAM<\/strong><\/h2>\n<div class=\"center_img\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/hev200ad.webp\" alt=\"hev200ad\" \/><\/div>\n<h2><strong>WIRING DIAGRAM<\/strong><\/h2>\n<div class=\"center_img\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/hev-ad_e.webp\" alt=\"hev-ad_e\" \/><\/div>\n<h2><strong>COIL TEMPERATURE CURVE<\/strong><\/h2>\n<div class=\"center_img\"><img decoding=\"async\" class=\"mw-100\" src=\"https:\/\/sayoon-dc.com\/wp-content\/uploads\/2026\/05\/xqws-hev200ah.webp\" alt=\"xqws-hev200ah\" \/><\/div>\n<h2><strong>MECHANICAL ABILITY and USE of the ENVIRONMENT<\/strong><\/h2>\n<div class=\"table-wrap\">\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\">\u00a0Contact lead M8 tightening torque (N.m)<\/td>\n<td valign=\"center\">\u00a0\u226f9.0 appropriate<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Coil lead mode<\/td>\n<td valign=\"center\">\u00a0Wire dipping tin (red positive and black negative)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Ambient temperature<\/td>\n<td valign=\"center\">\u00a0-40~+85\u2103<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Relative humidity<\/td>\n<td valign=\"center\">\u00a0+20\u2103 98%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Vibration freq. atthe fixed position<\/td>\n<td valign=\"center\">\u00a03G, 1\uff5e50Hz amplitude 0.5mm<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Concussion<\/td>\n<td valign=\"center\">\u00a0(60\uff5e100) time\/minute\u3001acceleration\u22644g<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Altitude<\/td>\n<td valign=\"center\">\u00a02000m<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Installation direction<\/td>\n<td valign=\"center\">\u00a0Random<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0International Protection<\/td>\n<td valign=\"center\">\u00a0IP68<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2><strong>ORDER INSTRUCTION<\/strong><\/h2>\n<div>\n<div class=\"table-wrap\">\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"center\">\n<p align=\"center\">\u00a0<b>SAYOON Product Type<\/b><\/p>\n<\/td>\n<td valign=\"center\">\n<p align=\"center\">\u00a0<b>HEV200<\/b><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0U.N.W.<\/td>\n<td valign=\"center\">\u00a0710g<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\">\u00a0Mounting bracket type<\/td>\n<td valign=\"center\">\u00a0L Vertical(default),M Horizontal<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div>\n<div>When ordering, please state the following: name, full model, control coil voltage specification, installation frame type, whether with auxiliary contact, order quantity. For example: HV DC Contactor HEV200-\u25a1-\u25a1\/24V 100pcs, indicating the load rated current 200A, without auxiliary contact, default mounting bracket, coil control voltage 24V purchase 100pcs. Special voltage specification products, such as user needs can be special order.<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<div class=\"sy-hev200-summary\" style=\"font-size:16px;line-height:1.6;color:#475569;\">\n<p style=\"margin:0 0 18px;\">SAYOON HEV200 l\u00e0 m\u1ed9t <strong>b\u1ed9 ti\u1ebfp x\u00fac DC k\u00edn epoxy resin 200A<\/strong> d\u00f9ng cho chuy\u1ec3n m\u1ea1ch DC \u0111i\u1ec7n \u00e1p cao. N\u00f3 c\u00f3 s\u1eb5n v\u1edbi c\u00e1c ti\u1ebfp x\u00fac th\u01b0\u1eddng m\u1edf ho\u1eb7c th\u01b0\u1eddng \u0111\u00f3ng, c\u00e1c \u0111i\u1ec7n \u00e1p cu\u1ed9n coil kh\u00e1c nhau v\u00e0 c\u00e1c ti\u1ebfp x\u00fac ph\u1ee5 t\u00f9y ch\u1ecdn. Ch\u1ecdn m\u00f4 h\u00ecnh ho\u00e0n ch\u1ec9nh ph\u00f9 h\u1ee3p v\u1edbi m\u1ea1ch t\u1ea3i v\u00e0 ngu\u1ed3n \u0111i\u1ec1u khi\u1ec3n c\u1ee7a b\u1ea1n.<\/p>\n<dl style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(145px,1fr));gap:12px 18px;margin:0 0 20px;padding:16px;background:#f1f7fb;border-left:3px solid #009fe3;border-radius:4px;\">\n<div>\n<dt style=\"font-size:13px;color:#526477;\">D\u00f2ng t\u1ea3i \u0111\u1ecbnh m\u1ee9c<\/dt>\n<dd style=\"margin:0;font-weight:700;color:#142c43;\">200A (DC-1)<\/dd>\n<\/div>\n<div>\n<dt style=\"font-size:13px;color:#526477;\">T\u00f9y ch\u1ecdn \u0111i\u1ec7n \u00e1p ti\u1ebfp x\u00fac<\/dt>\n<dd style=\"margin:0;font-weight:700;color:#142c43;\">200V \/ 1000V DC<\/dd>\n<\/div>\n<div>\n<dt style=\"font-size:13px;color:#526477;\">T\u00f9y ch\u1ecdn ti\u1ebfp x\u00fac ch\u00ednh<\/dt>\n<dd style=\"margin:0;font-weight:700;color:#142c43;\">1 NO \/ 1 NC<\/dd>\n<\/div>\n<div>\n<dt style=\"font-size:13px;color:#526477;\">V\u00ed d\u1ee5 v\u1ec1 \u0111i\u1ec7n \u00e1p cu\u1ed9n coil<\/dt>\n<dd style=\"margin:0;font-weight:700;color:#142c43;\">12V \/ 24V \/ 48V DC<\/dd>\n<\/div>\n<div>\n<dt style=\"font-size:13px;color:#526477;\">C\u00e1c terminal t\u1ea3i<\/dt>\n<dd style=\"margin:0;font-weight:700;color:#142c43;\">Terminal v\u00edt M8<\/dd>\n<\/div>\n<div>\n<dt style=\"font-size:13px;color:#526477;\">Gi\u00e1 \u0111\u1ee1 l\u1eafp \u0111\u1eb7t<\/dt>\n<dd style=\"margin:0;font-weight:700;color:#142c43;\">D\u1ecdc \/ ngang<\/dd>\n<\/div>\n<\/dl>\n<h3 style=\"font-size:18px;line-height:1.35;margin:0 0 8px;color:#142c43;\">\u1ee8ng d\u1ee5ng &amp; l\u1ef1a ch\u1ecdn<\/h3>\n<p style=\"margin:0 0 16px;\">Xem x\u00e9t HEV200 cho m\u1ea1ch ngu\u1ed3n xe \u0111i\u1ec7n, thi\u1ebft b\u1ecb s\u1ea1c EV, UPS v\u00e0 c\u00e1c h\u1ec7 th\u1ed1ng \u0111i\u1ec1u khi\u1ec3n DC kh\u00e1c. X\u00e1c nh\u1eadn \u0111i\u1ec7n \u00e1p DC t\u1ed1i \u0111a, d\u00f2ng li\u00ean t\u1ee5c, nhi\u1ec7m v\u1ee5 \u0111\u00f3ng\/ng\u1eaft, lo\u1ea1i t\u1ea3i v\u00e0 \u0111i\u1ec1u ki\u1ec7n m\u00f4i tr\u01b0\u1eddng tr\u01b0\u1edbc khi ch\u1ecdn phi\u00ean b\u1ea3n. C\u00e1c t\u00f9y ch\u1ecdn \u0111i\u1ec7n \u00e1p tr\u00ean kh\u00f4ng c\u00f3 ngh\u0129a l\u00e0 m\u1ecdi phi\u00ean b\u1ea3n \u0111\u1ec1u c\u00f3 th\u1ec3 ng\u1eaft 200A t\u1ea1i 1000V DC.<\/p>\n<h3 style=\"font-size:18px;line-height:1.35;margin:0 0 8px;color:#142c43;\">Ch\u1ec9 \u0111\u1ecbnh c\u1ea5u h\u00ecnh HEV200 c\u1ee7a b\u1ea1n<\/h3>\n<p style=\"margin:0;\">G\u1eedi \u0111i\u1ec7n \u00e1p bus DC, d\u00f2ng t\u1ea3i, ngu\u1ed3n cung coil, y\u00eau c\u1ea7u NO\/NC, y\u00eau c\u1ea7u ti\u1ebfp x\u00fac ph\u1ee5, h\u01b0\u1edbng v\u00e0 s\u1ed1 l\u01b0\u1ee3ng gi\u00e1 \u0111\u1ee1. Y\u00eau c\u1ea7u b\u1ea3n v\u1ebd ph\u00f9 h\u1ee3p v\u00e0 th\u00f4ng s\u1ed1 chuy\u1ec3n m\u1ea1ch c\u00f9ng b\u00e1o gi\u00e1 c\u1ee7a b\u1ea1n. Xem c\u00e1c b\u1ea3ng k\u1ef9 thu\u1eadt v\u00e0 s\u01a1 \u0111\u1ed3 l\u1eafp \u0111\u1eb7t d\u01b0\u1edbi \u0111\u00e2y \u0111\u1ec3 bi\u1ebft th\u00eam chi ti\u1ebft.<\/p>\n<\/div>","protected":false},"featured_media":1393,"template":"","meta":{"_gspb_post_css":""},"product_brand":[],"product_cat":[51],"product_tag":[],"class_list":["post-1397","product","type-product","status-publish","has-post-thumbnail","product_cat-hev-series-hv-dc-contactor","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/sayoon-dc.com\/vi\/wp-json\/wp\/v2\/product\/1397","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sayoon-dc.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sayoon-dc.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sayoon-dc.com\/vi\/wp-json\/wp\/v2\/media\/1393"}],"wp:attachment":[{"href":"https:\/\/sayoon-dc.com\/vi\/wp-json\/wp\/v2\/media?parent=1397"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/sayoon-dc.com\/vi\/wp-json\/wp\/v2\/product_brand?post=1397"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/sayoon-dc.com\/vi\/wp-json\/wp\/v2\/product_cat?post=1397"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/sayoon-dc.com\/vi\/wp-json\/wp\/v2\/product_tag?post=1397"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}