SZJ400A Normally Open DC Contactor

SZJ400A Normally Open DC Contactor

Discover the SZJ400A Normally Open DC Contactor for reliable performance in various applications. Perfect for your electrical needs. Buy now for optimal efficiency!
Overview

FEATURES

The applications of normally open DC contactors are very wide-ranging. From motor start and stop control to automation equipment power management, the device is an integral part of numerous electrical systems. It is also widely used in renewable energy applications, such as controlling solar and wind energy systems, where efficient power management is essential. In addition, contactors have a place in traffic lights and other control systems, demonstrating their versatility and adaptability in different fields.

SAYOON MODEL IMPLICATION

SZJ

400A

-S

-□

-□

/□

1

2

3

4

5

6

1

Product type                

2

Rated current                

3

Auxiliary switch: None-Without auxiliary switch; S-With auxiliary switch  

4

Mounting bracket type: None-M Horizontal (default); E-Level embedded; L(N)-Vertical; E1-Level embedded single direction; E2-Level embedded single direction

5

Other function codes

6

Coil rated voltage: 12V, 24V, 36V, 48V, 60V, 72V etc.

Uses

This product have one normally open contact, for electric vehicles, telecommunication equipment, engineering machinery, car batteries, electric forklift trucks, trains, ships, electronic control systems such as uninterruptible power supply.

Technical Parameters:  (Version 2.46)

 SAYOON Product Type

 SZJ400A

 Contact form

 1 NO

 Coil Rated voltage (DC V)

 6V,12V,24V,36V,48V,60V,72V,84V,120V,150V etc.

 Contact voltage (DC V)

 ≤60V

 Rated load current of contact 48V circuit (A)

 400A

 Typical voltage drop across contacts per 100A

 ≯80mV

 The cooling pull-in voltage at (20±5)℃ (V)

 ≯70%

 The cooling drop-out voltage at (20±5)℃ (V)

 ≯40%,≮5%

 Working voltage range of 40℃ coil

 0.8-1.2Us

 Drop-out time (n/o contacts to open)

 25ms

 Pull-in time (n/o contacts to close)

 10ms

 Maximum bounce time for contact connection

 10ms

 Maximum bounce time for contact disconnection

 3ms

 Insulation resistance

 20MΩ

 Electric strength to resist

 50Hz/60Hz 1000VAC 1minute

 Typical fault currents which can be ruptured

 1500A/5ms at 48V DC

 Coil power (W)

 Start: 120-170, Keep: 5-11

 Temperature rise of coil (K)

 ≤45

 Temperature rise on outgoing terminal (K)

 ≤65

 Electrical life

 20,000 times

 Mechanical life

 300,000 times

 Work specification

 Continuous

 Contact material

 Ag alloy

 Load terminal type

 M10 Screw

 Coil terminal type

 M4 Screw

 Auxiliary contact rated load (optional)

 2A/48VDC, 5A/24VDC

 Testing organization certification

 CCC,CE,FCC,RoHS


Note:As regarding to the different using environments of customers which requires different focus of the functions,and in order to improve the comprehensive properties of our products,sayoon may adjust the coil parameters,temperature rise and so on. The above parameters are for reference only, For details, please refer to the guidelines for selection and use of the SAYOON DC contactor.

Load Characteristic Curve

  • HEV400 HV DC Contactor detail (3)
  • HEV400 HV DC Contactor detail (2)

Installation Diagram

szj400aszj400a-sszj400a-e2

Wiring Diagram

szj-10_e

Temperature Curve

xqws-szj200a

Mechanical Ability And Use Of The Environment

 Contact lead M10 tightening torque (N.m)

 ≯20.5 appropriate

 Coil lead M4 tightening torque (N.m)

 ≯1.2 appropriate

 Ambient temperature

 -25~+70℃

 Relative humidity

 +20℃ 98%

 Vibration freq. atthe fixed position

 3G, 1~50Hz amplitude 0.5mm

 Concussion

 (60~100) time/minute、acceleration≤4g

 Altitude

 2000m

 Installation direction

 Random

 International protection

 IP40 (According IEC60947)

Order Instruction

 SAYOON Product Type

 SZJ400A

 U.N.W.

 883g

 U.G.W.

 959g

 Package QTY.

 20PCS

 Mounting bracket type

 None – M Horizontal (default), E Level Embedded, L (N) Vertical, E1 Level embedded single direction, E2 Level Embedded


When ordering, please state the following: name, full model, control coil voltage specification, installation frame type, whether with auxiliary contact, order quantity. For example: DC Contactor SZJ400A/24V 100pcs, indicating the load rated current 400A, without auxiliary contact, default mounting bracket, coil control voltage 24V purchase 100pcs. Special voltage specification products, such as user needs can be special order.

Request a Custom Quote

Interested in this product? Fill out the form below and our sales team will get back to you within 24 hours.

Contact Form
WhatsApp
WhatsApp QR Code
WeChat
WeChat Code
Phone
+86 130 5791 2357
Email
sayoon@sayoon.com