CZWH400A-T SPDT DC Contactor

CZWH400A-T SPDT DC Contactor

Discover the CZWH400A-T SPDT DC Contactor for reliable switching solutions. Ideal for various applications it ensures efficient performance and durability. Buy now!
Overview

FEATURES

 The key feature of the SPDT DC contactor is its single-pole, double-throw design. This configuration allows the contactor to connect a single input to one of two outputs, enabling the user to select between two different circuits. This feature is particularly useful in applications where circuit selection or alternation is required, such as in motor control systems or lighting configurations. The ability to switch between two outputs using a single input enhances the versatility of the contactor, making it a valuable asset in both industrial and residential environments.
 SPDT DC contactors are designed for DC operation and are optimized to operate effectively under DC conditions. Unlike AC devices, which may not operate reliably in DC applications, SPDT contactors are designed to handle the unique characteristics of DC voltage. This makes them ideal for electric vehicles, renewable energy systems such as solar power generation, and other applications where DC power is the norm. Its stability under DC conditions ensures that it can reliably provide consistent performance in critical applications.

SAYOON MODEL IMPLICATION

CZWH

400A

-T

-S

-C

-M

-□

/24V

1

2

3

4

5

6

7

8

1

Product type

2

Rated current

3

Circuit structure: Single coil, single circuit

4

Auxiliary switch: None-Without auxiliary switch; S-With auxiliary switch

5

Magnetic blow-out

6

Mounting bracket type: M-Horizontal (default); L-One vertical; 2L-Two vertical

7

Other function codes: l-With suppressor diode; R-With pre-charged resistance; CO-Continuous; IN-Intermittent

8

Coil rated voltage: 12V, 24V, 36V, 48V, 60V, 72V etc.

Uses

This product have one normally open and one normally close contact, for electric vehicles, telecommunication equipment, engineering machinery, car batteries, electric forklift trucks, trains, ships, electronic control systems such as uninterruptible power supply.

Technical Parameters:  (Version 1.57)

 SAYOON Product Type

 CZWH400A

 Contact form  1 NO 1 NC
 Coil Rated voltage (DC V)  6V,12V,24V,36V,48V,60V,72V,84V,120V,150V,220V etc.
 Contact voltage (DC V)  ≤80V
 Rated load current of contact 48V circuit (DC-1)  400A
 Typical voltage drop across contacts per 100A  ≯80mV
 The cooling pull-in voltage at (20±5)℃ (V)  ≯70%
 The cooling drop-out voltage at (20±5)℃ (V)  ≯35%,≮5%
 Working voltage range of 40℃ coil  0.8-1.2Us
 Drop-out time (n/o contacts to open)  40ms
 Pull-in time (n/o contacts to close)  12ms
 Maximum bounce time for contact connection  10ms
 Maximum bounce time for contact disconnection  3ms
 Insulation resistance  20MΩ
 Electric strength to resist  50Hz/60Hz 1000VAC 1minute
 Typical fault currents which can be ruptured  1500A/5ms at 48V DC
 Coil power (W)  22-40
 Temperature rise of coil (K)  ≤80
 Temperature rise on outgoing terminal (K)  ≤65
 Electrical life  20,000 times
 Mechanical life  300,000 times
 Work specification  Continuous or Intermittent(default)
 Contact material  Ag alloy
 Load terminal type  M10 Screw
 Coil terminal type  6.3mm spade terminals
 Auxiliary contact rated load (optional)  2A/48VDC, 5A/24VDC
 Normally closed to normally open  14ms
 Normally open to normally closed  8ms
 Testing organization certification  CE,FCC

 

Note:As regarding to the different using environments of customers which requires different focus of the functions,and in order to improve the comprehensive properties of our products,sayoon may adjust the coil parameters,temperature rise and so on. The above parameters are for reference only, For details, please refer to the guidelines for selection and use of the SAYOON DC contactor.

Load Characteristic Curve

  • HEV400 HV DC Contactor detail (3)
  • HEV400 HV DC Contactor detail (2)

Installation Diagram

czwh400aczwh400a-sczwh400a_1

Wiring Diagram

SEV600AH HV DC Contactor detail (4)

Temperature Curve

SEV600AH HV DC Contactor detail (4)

Mechanical Ability And Use Of The Environment

 Contact lead M10 tightening torque (N.m)  ≯20.5 appropriate
 Coil lead-out torque (N.m)  ≯0.8 appropriate
 Ambient temperature  -25~+70℃
 Relative humidity  +20℃ 98%
 Vibration freq. atthe fixed position  3G, 1~50Hz amplitude 0.5mm
 Concussion  (60~100) time/minute、acceleration≤4g
 Altitude  2000m
 Installation direction  Random
 International protection  IP40 (According IEC60947)

Order Instruction

 SAYOON Product Type

 CZWH400A

 U.N.W.  1593g
 Package QTY.  20PCS
 Mounting bracket type  M Horizontal (default), 1L One vertical, 2L Two vertical

 

When ordering, please state the following: name, full model, control coil voltage specification, installation frame type, whether with auxiliary contact, order quantity. For example: DC Contactor CZWH400A/24V 100pcs, indicating the load rated current 400A, without auxiliary contact, default mounting bracket, coil control voltage 24V purchase 100pcs. Special voltage specification products, such as user needs can be special order.

Request a Custom Quote

Interested in this product? Fill out the form below and our sales team will get back to you within 24 hours.

Formulario de Contacto
WhatsApp
WhatsApp QR Code
WeChat
WeChat Code
Phone
+86 130 5791 2357
Email
sayoon@sayoon.com